Objective: To analyse the effects of titanium implants coated with various antimicrobial peptide (AMP) layers on bacterial growth and early biofilm formation around the implants.

Methods: A novel AMP mixture was constructed using Type I collagen, sulfonated succinimide 4- (N-Maleimidylphenyl) butyrate, and AMPs. Titanium discs treated with chitosan and hyaluronic acid solutions were reacted with the AMP mixture to obtain AMP-coated titanium discs. The drug release properties and inhibitory effects on the growth and early biofilm formation of Porphyromonasgingivalis (P. gingivalis) ATCC BAA-308 or Staphylococcus aureus (S. aureus) ATCC 25923 were analysed.

Results: The antimicrobial activity of the 9-layer AMP-coated titanium discs against P. gingivalis ATCC BAA-308 and S.aureus ATCC 25923 was greatly higher relative to the 3-layer and 6-layer AMP-coated titanium discs (P < .05). The overall optical density and average optical density of titanium discs coated with 6 and 9 layers of AMPs were markedly inferior to those of uncoated titanium discs and discs coated with 3 layers of AMPs (P < .05). The drug release amounts from titanium discs coated with different layers of AMPs increased over time.

Conclusions: The prepared AMP-coated titanium discs effectively inhibit the growth of P. gingivalis and S. aureus, as well as early biofilm formation. The drug-laced discs demonstrate good durability and predictability in drug release, which may be beneficial for long-term therapeutic adoption.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.identj.2024.11.001DOI Listing

Publication Analysis

Top Keywords

titanium discs
32
amp-coated titanium
16
early biofilm
12
biofilm formation
12
drug release
12
discs coated
12
coated layers
12
layers amps
12
discs
10
titanium
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!