Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Doppler ultrasound can be used to evaluate leg blood flow (Q̇), especially of interest when investigating peripheral vascular limitations in patients with chronic obstructive pulmonary disease (COPD). However, the within-session repeatability, a subdomain of test-retest reliability, of this method remains unknown. This study aimed to provide within-session repeatability estimates of Doppler ultrasound-based Q̇ at rest and during single-leg knee-extensor exercise (KEE) in patients with COPD, and to compare these estimates to matched healthy controls. In this case-controlled study, 16 participants with COPD were matched based on sex and age with 16 healthy controls. All participants underwent measurement of Q̇ using Doppler ultrasound in a KEE setup at various intensities with the same measurement being performed again separated by 10 s. Smallest real difference (SRD) was lowest at rest in both groups and increased during exercise, reaching values ranging from 164 to 231 mL in COPD and 122-180 mL in the control group. The coefficient of variance (CV) was highest at rest and decreased during exercise to values ranging from 4.0% to 5.0% in COPD and 2.6%-3.2% in the control group. The CV was significantly lower in the control group during 0 watt and exercise at 20% of max watt, but apart from that, no reliability estimates were different between groups. To conclude, Doppler ultrasound showed nearly equal within-session repeatability when evaluating Q̇ in COPD patients and healthy individuals with a CV not exceeding 5% during exercise for both groups.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cpf.12919 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!