Fibre optic probe based Raman spectroscopy can deliver molecular compositional analysis of a range of diseases. However, some biological tissues exhibit high levels of fluorescence which limit the utility of the technique, particularly when the fluorescence induces CCD etaloning, which can be particulalry hard to remove in subsequent analysis. Furthermore, use of fibre probes can result in silica signals superimposed on the biological Raman signals. Shifted excitation Raman difference spectroscopy (SERDS) utilises a small seperation in excitation wavelengths to remove signals from fluorescence, room lights, optical components and etaloning contributions, while retaining chemical signals from the sample. In this study, we sought to measure the optimum SERDS spectra enabling reconstruction of a range a narrow and broad peaks found in biological samples. A original wavelength of 830 nm was utilised with 7 different shifts between 0.4 and 3.9 nm to determine which gave the best performance. This range roughly corresponds to the typical range of peak widths within biological Raman spectra at 830 nm excitation; 0.41 - 3.25 nm or 6 - 47 cm. An wavelength shift of 2.4 nm was identified as optimal. Finally, a fibre optic Raman probe was used to measure 2 human lymph nodes to demonstrate the feasibility of the approach with real-world examples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d4an01264j | DOI Listing |
Sci Rep
December 2024
College of Computer Science, Chengdu University, Chengdu, 610106, China.
This study offers a comprehensive analysis of the Perturbed Schrödinger -Hirota Equation (PSHE), crucial for understanding soliton dynamics in modern optical communication systems. We extended the traditional Nonlinear Schrödinger Equation (NLSE) to include higher-order nonlinearities and spatiotemporal dispersion, capturing the complexities of light pulse propagation. Employing the modified auxiliary equation method and Adomian Decomposition Method (ADM), we derived a spectrum of exact traveling wave solutions, encompassing exponential, rational, trigonometric, and hyperbolic functions.
View Article and Find Full Text PDFJ Biophotonics
December 2024
Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas, USA.
We report on the development of a multimodal spectroscopy system, combining diffuse reflectance spectroscopy (DRS) and spatially offset Raman spectroscopy (SORS). A fiber optic probe was designed with spatially offset source-detector fibers to collect subsurface measurements for each modality, as well as ball lens-coupled fibers for superficial measurements. The system acquires DRS, zero-offset Raman spectroscopy (RS) and SORS with good signal-to-noise ratio.
View Article and Find Full Text PDFJ Dent
December 2024
Faculty of Dentistry, The University of Hong Kong, Hong Kong, S.A.R., China. Electronic address:
Objective: To evaluate and compare the accuracy of detection methods for the diagnosis of secondary caries around direct restorations in posterior teeth.
Data: Accuracy parameters including sensitivity, specificity, diagnostic odds ratio (DOR), area under curve (AUC), and partial AUC (pAUC) are generated from studies assessing the accuracy of detection methods for secondary caries.
Sources: Publications from PubMed, Web of Science, Scopus, Medline, EMBASE and Cochrane Library databases.
Ophthalmology
December 2024
John P. Hussman Institute for Human Genomics, University of Miami, FL; Dr. John T. Macdonald Foundation Department of Human Genetics, University of Miami, FL.
Purpose: To investigate the association between epigenetic age acceleration and glaucoma progression.
Design: Retrospective cohort study.
Participants: 100 primary open-angle glaucoma (POAG) patients with fast progression and 100 POAG patients with slow progression.
Radiother Oncol
December 2024
Department of Radiotherapy, UZ Brussel, Vrije Universiteit Brussel, 1090 Brussels, Belgium. Electronic address:
Background And Purpose: Tumor hypoxia is the principal cause of clinical radioresistance. Despite its established role as radiosensitizer, hydrogen peroxide (HO) encounters clinical limitations due to stability and toxicity concerns. Recent advancements in drug delivery combine HO with sodium hyaluronate (SH), enabling intratumoral administration of HO.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!