Inhaler errors inversely affect the outcome of respiratory diseases. Inhaler devices, such as the metered-dose inhalers (MDI) and dry powder inhalers (DPI), are commonly used in treating respiratory diseases like asthma and chronic obstructive pulmonary disease (COPD), and incorrect use of these devices can result in suboptimal treatment outcomes, increased probabilities of hospitalizations or admissions, and poorer quality of life. Patient related factors to inhaler errors include age, cognitive and physical abilities, education, language barriers, and preferences. Device-related factors such as inhaler design and operational complexity can also lead to errors. Finally, factors related to healthcare professionals (HCP) such as competency, level of knowledge in disease and inhaler device and availability to educate patients, can play a role in inhaler error. Quality management is a potential solution to this problem. Quality improvement strategies towards addressing inhaler misuse can increase patient satisfaction and improve patient outcomes. Donabedian's triad, which includes structure, process, and outcome can be utilized in developing a framework for reducing inhaler errors. Institutional solutions are more towards the structural and process changes in the triad, such as HCP training, checklists on training efficacy, provision of action plans, and availability of staff to educate and train patients. Patient-centered solutions focus more on process and outcome domains, such as improvement in lung functions, patient education, re-assessment and re-education of inhaler techniques, and adherence to treatment regimen. By focusing on structural and process domains, the quality of care can be enhanced, resulting in improved outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603695 | PMC |
http://dx.doi.org/10.3389/fmedt.2024.1494089 | DOI Listing |
JMIR Perioper Med
January 2025
Stanford Hospital, Stanford, CA, United States.
Background: Inhalational anesthetic agents are a major source of potent greenhouse gases in the medical sector, and reducing their emissions is a readily addressable goal. Nitrous oxide (NO) has a long environmental half-life relative to carbon dioxide combined with a low clinical potency, leading to relatively large amounts of NO being stored in cryogenic tanks and H cylinders for use, increasing the chance of pollution through leaks. Building on previous findings, Stanford Health Care's (SHC's) NO emissions were analyzed at 2 campuses and targeted for waste reduction as a precursor to system-wide reductions.
View Article and Find Full Text PDFMonaldi Arch Chest Dis
January 2025
Department of Pharmacy Practice, KLE College of Pharmacy, Belagavi, KLE Academy of Higher Education and Research, Karnataka.
Individuals with chronic obstructive pulmonary disease (COPD) and cognitive impairment (CI) often face difficulties accurately administering inhalers, which are essential for managing their respiratory condition. Many elderly individuals make major errors that prevent proper medicine administration. Maintaining proper inhaler use skills is critical in controlling COPD.
View Article and Find Full Text PDFInt J Chron Obstruct Pulmon Dis
January 2025
School of Nursing and Health Sciences Hong Kong Metropolitan University, Hong Kong Special Administrative Region, People's Republic of China.
Background: Persistently high rates of inhaler errors and poor adherence among Chronic Obstructive Pulmonary Disease (COPD) patients contribute to ineffective symptomatic control, high care burdens, and increased healthcare resource utilization.
Objective: This study aimed to report (i) nurses-identified common problems and errors of inhaler use in COPD patients, (ii) nurses' attitudes, practices, training needs and required support in inhaler education.
Methods: An online questionnaire survey was conducted with nurses working in Hong Kong from May to June 2023 using an exponential, non-discriminative snowball sampling strategy.
Sci Total Environ
January 2025
Center for Environmental Measurement and Modeling, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711, USA.
Epidemiologic studies of ambient fine particulate matter (PM) and ozone (O) often use outdoor concentrations from central-site monitors or air quality model estimates as exposure surrogates, which can result in exposure errors. We previously developed an exposure model called TracMyAir, which is an iPhone application that determines seven tiers of individual-level exposure metrics for ambient PM and O using outdoor concentrations, home building characteristics, weather, time-activities. The exposure metrics with increasing information needs and complexity include: outdoor concentration (C, Tier 1), building infiltration factor (F, Tier 2), indoor concentration (C, Tier 3), time spent in microenvironments (ME) (T, Tier 4), personal exposure factor (F, Tier 5), exposure (E, Tier 6), and inhaled dose (D, Tier 7).
View Article and Find Full Text PDFChronic Obstr Pulm Dis
December 2024
Department of Medicine, Queen Mary Hospital, University of Hong Kong, Pokfulam, Hong Kong Special Administrative Region, China.
Background: Triple therapy with inhaled corticosteroids and dual bronchodilator was recommended in chronic obstructive pulmonary disease (COPD) patients who had exacerbations and eosinophilia. It can be administered by single inhaler (SITT) or multiple inhaler (MITT). There was lack of evidence of the benefits of SITT over MITT in Chinese population, especially on switching from existing MITT to SITT.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!