A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility of newly designed rotatable sphincterotome for endoscopic sphincterotomy (with video). | LitMetric

Endoscopic sphincterotomy can be challenging especially in patients with surgically altered anatomy. Although a rotatable sphincterotome (r-sphincterotome) may be useful, its rotational function is often inadequate. We evaluated the feasibility of a newly designed r-sphincterotome equipped with a well-conceived cutting wire. We measured the movement and dynamics of both the newly designed r-sphincterotome and two existing r-sphincterotomes using in-house equipment. Ideally, the rotational force exerted at the proximal end should transmit directly to the distal end. But it is often challenging, particularly within the constraints of a bent endoscope and working channel. We collected data regarding deviation from the ideal value 10 times for each sphincterotome. The deviation from the ideal value was significantly lower with the newly designed r-sphincterotome than with the conventional r-sphincterotomes (44.9 ± 27.8 vs. 73.7 ± 44.6 and 130.1 ± 71.4 degrees, respectively; < 0.001). The newly designed r-sphincterotome rotated smoothly and consistently at a constant speed, mirroring the input rotation. We evaluated the feasibility of the newly designed r-sphincterotome using an experimental model. We believe that the findings from these experiments may contribute to easier and more precise sphincterotomies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11604308PMC
http://dx.doi.org/10.1055/a-2422-2425DOI Listing

Publication Analysis

Top Keywords

newly designed
24
designed r-sphincterotome
20
feasibility newly
12
rotatable sphincterotome
8
endoscopic sphincterotomy
8
evaluated feasibility
8
deviation ideal
8
designed
6
r-sphincterotome
6
newly
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!