Sample efficient approaches in time-resolved X-ray serial crystallography and complementary X-ray emission spectroscopy using drop-on-demand tape-drive systems.

Methods Enzymol

Diamond Light Source, Harwell Science & Innovation Campus, Didcot, United Kingdom; Research Complex at Harwell, Rutherford Appleton Laboratory, Didcot, United Kingdom. Electronic address:

Published: November 2024

Dynamic structural biology enables studying biological events at the atomic scale from 10's of femtoseconds to a few seconds duration. With the advent of X-ray Free Electron Lasers (XFELs) and 4th generation synchrotrons, serial crystallography is becoming a major player for time-resolved experiments in structural biology. Despite significant progress, challenges such as obtaining sufficient amounts of protein to produce homogeneous microcrystal slurry, remain. Given this, it has been paramount to develop instrumentation that reduces the amount of microcrystal slurry required for experiments. Tape-drive systems use a conveyor belt made of X-ray transparent material as a motorized solid-support to steer deposited microcrystals into the beam. For efficient sample consumption on-demand ejectors can be synchronized with the X-ray pulses to expose crystals contained in droplets deposited on the tape. Reactions in the crystals can be triggered via various strategies, including pump-probe, substrate/ligand mixing, or gas incubation in the space between droplet ejection and X-ray illumination. Another challenge in time-resolved serial crystallography is interpreting the resulting electron density maps. This is especially difficult for metalloproteins where the active site metal is intimately involved in catalysis and often proceeds through multiple oxidation states during enzymatic catalysis. The unrestricted space around tape-drive systems can be used to accommodate complementary spectroscopic equipment. Here, we highlight tape-drive sample delivery systems for complementary and simultaneous X-ray diffraction (XRD) and X-ray emission spectroscopy (XES) measurements. We describe how the combination of both XRD and XES is a powerful tool for time-resolved experiments at XFELs and synchrotrons.

Download full-text PDF

Source
http://dx.doi.org/10.1016/bs.mie.2024.10.008DOI Listing

Publication Analysis

Top Keywords

serial crystallography
12
tape-drive systems
12
x-ray
8
x-ray emission
8
emission spectroscopy
8
structural biology
8
time-resolved experiments
8
microcrystal slurry
8
sample efficient
4
efficient approaches
4

Similar Publications

Serial macromolecular crystallography has become a powerful method to reveal room temperature structures of biological macromolecules and perform time-resolved studies. ID29, a flagship beamline of the ESRF 4th generation synchrotron, is the first synchrotron beamline in the world capable of delivering high brilliance microsecond X-ray pulses at high repetition rate for the structure determination of biological macromolecules at room temperature. The cardinal combination of microsecond exposure times, innovative beam characteristics and adaptable sample environment provides high quality complete data, even from an exceptionally small amount of crystalline material, enabling what we collectively term serial microsecond crystallography (SµX).

View Article and Find Full Text PDF

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals.

View Article and Find Full Text PDF

G protein-coupled receptors (GPCRs) are the largest family of cell surface receptors in humans. The binding and dissociation of ligands tunes the inherent conformational flexibility of these important drug targets towards distinct functional states. Here we show how to trigger and resolve protein-ligand interaction dynamics within the human adenosine A receptor.

View Article and Find Full Text PDF

Alanine racemase (Alr) catalyzes the pyridoxal 5'-phosphate (PLP)-dependent racemization between L- and D-alanine in bacteria. Owing to the potential interest in targeting Alr for antibacterial drug development, several studies have determined the structures of Alr from different species, proposing models for the reaction mechanism. Insights into its reaction dynamics may be conducive to a better understanding of the Alr reaction mechanism.

View Article and Find Full Text PDF

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework.

View Article and Find Full Text PDF