Background: The purpose of this study was to evaluate the efficacy of selective laser sintering (SLS) against the traditional casting method in fabricating customized Co-Cr dental posts, employing 3D coordinate metrology for analysis.

Methods: A 10 mm post space was prepared in a transparent acrylic block using a red ParaPost XP drill (1.25 mm diameter). An impression of this cavity was taken with a 1.143 mm diameter ParaPost impression post and auto-polymerizing acrylic resin. The resin patterns obtained were digitized with a Straumann Cares scanner, generating STL files, which were forwarded to Renishaw for the production of 10 Co-Cr posts through SLS. Simultaneously, the original resin patterns underwent investment and casting in Co-Cr alloy. The dimensional accuracy of the posts produced by both methods was evaluated using the triple scan method.

Results: The mean discrepancy was - 0.048 mm when comparing the dimensions of scanned resin posts to those of the conventionally cast posts, and - 0.067 mm between the scanned SLS-produced posts and the original resin patterns. Statistical analysis indicated no significant difference between the two sets of mean values (P = 0.107).

Conclusion: SLS technology is a viable alternative to the conventional casting technique for the manufacture of customized Co-Cr posts. Furthermore, SLS offers advantages in terms of cost and time efficiency without compromising the accuracy of the end product.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603624PMC
http://dx.doi.org/10.1186/s13104-024-07011-3DOI Listing

Publication Analysis

Top Keywords

resin patterns
12
posts
8
selective laser
8
laser sintering
8
conventional casting
8
customized co-cr
8
co-cr posts
8
posts sls
8
original resin
8
resin
5

Similar Publications

Aim: This study evaluates long-term shear bond strength (SBS) and enamel micro cracks (MCs) healing after using adhesive pre-coated brackets (APC).

Materials And Methods: A total of eighty extracted human premolar teeth were randomly divided into four experimental groups ( = 20 per group): Control group: Teeth underwent indentation but no bracket bonding; group II : Teeth were subjected to indentation without exposure to thermocycling; group III: Teeth experienced both indentation and thermocycling; group IV: No indentation was applied to the teeth; groups III and IV were further divided into two subgroups to simulate different clinical timelines: Subgroup A (n = 10): Teeth underwent 5,000 thermocycles, equivalent to six months of clinical use. Subgroup B (n = 10): Teeth were subjected to 10,000 thermocycles, representing 12 months of use.

View Article and Find Full Text PDF

Evaluation of anion exchange resin for sorption of selenium (IV) from aqueous solutions.

BMC Chem

January 2025

Nuclear Chemistry Department, Hot Laboratories Center, Egyptian Atomic Energy Authority, P.O. 13759, Cairo, Egypt.

In this work, selenium (IV) ions were adsorbed from aqueous solutions by the strongly basic anion exchange resin Amberlite IRA-400. The morphology of the resin before and after Se(IV) sorption was investigated using different techniques such as energy dispersive X-ray spectroscopy (EDX), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). To determine the ideal sorption conditions, a batch approach was used to examine the variables affecting Se(IV) sorption performance, including pH, shaking time, adsorbent dosage, initial metal ion concentration, and temperature.

View Article and Find Full Text PDF

Predicting purification process fit of monoclonal antibodies using machine learning.

MAbs

December 2025

Department of Purification, Microbiology and Virology, Genentech Inc, South San Francisco, CA, USA.

In early-stage development of therapeutic monoclonal antibodies, assessment of the viability and ease of their purification typically requires extensive experimentation. However, the work required for upstream protein expression and downstream purification development often conflicts with timeline pressures and material constraints, limiting the number of molecules and process conditions that can reasonably be assessed. Recently, high-throughput batch-binding screen data along with improved molecular descriptors have enabled development of robust quantitative structure-property relationship (QSPR) models that predict monoclonal antibody chromatographic binding behavior from the amino acid sequence.

View Article and Find Full Text PDF

A highly stretchable, self-healing, self-adhesive polyacrylic acid/chitosan multifunctional composite hydrogel for flexible strain sensors.

Carbohydr Polym

March 2025

State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, 15 North Third Ring Road East, Chaoyang District, Beijing 100029, China. Electronic address:

Conductive hydrogels have emerged as excellent candidates for the design and construction of flexible wearable sensors and have attracted great attention in the field of wearable sensors. However, there are still serious challenges to integrating high stretchability, self-healing, self-adhesion, excellent sensing properties, and good biocompatibility into hydrogel wearable devices through easy and green strategies. In this paper, multifunctional conductive hydrogels (PCGB) with good biocompatibility, high tensile (1694 % strain), self-adhesive, and self-healing properties were fabricated by incorporating boric acid (BA) and glucose (Glu) simultaneously into polyacrylic acid (PAA) and chitosan (CS) polymer networks using a simple one-pot polymerization method.

View Article and Find Full Text PDF

Purpose: To investigate how varying ferrule heights and the number of glass fiber posts affect fracture resistance and behavior of endodontically treated maxillary first premolars with substantial loss of tooth structure.

Materials And Methods: Twenty-four extracted endodontically treated human maxillary first premolars were divided into three groups (n = 8) based on ferrule height and post number. The groups were as follows: premolars of 2 mm ferrule height that were restored with single posts (control group), premolars of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!