Aiming at the magnetic seal in an aero-engine accessory, the range of magnetic force required for the normal operation of the magnetic seal is analyzed. The finite element analysis method based on the Maxwell stress tensor method is used to calculate the magnetic force between the dynamic ring and the magnetic static ring in the magnetic sealing system. The magnetic force under different magnetization modes and gaps is tested by the magnetic measuring test bench, which verifies the correctness of the magnetic calculation method. The effects of permanent magnet material, permanent magnet magnetization direction, magnetic seal structural parameters, and working conditions on the magnetic force between the dynamic ring/magnetic static ring in the magnetic seal are analyzed. Under the same structure, the magnetic force of NeFeB35, SmCo28, Alnico5, and Ferrite as magnetic static rings is compared. The results show that NdFeB35 has the largest magnetic force, SmCo28 is second, Alnico5 and Ferrite are relatively small, and their magnetic forces are about 1/4 to 1/5 of the first two materials. When the rotor or the casing is moving axially, NeFeB35 and SmCo28 materials with large magnetic force should be selected to meet the normal working requirements. Under the same material, the magnetic forces of axial, radial, and radiative magnetization modes are compared. the ratio of magnetic force under axial, radiative, and radial magnetization is about 2.3:1.1:1. If NeFeB35 and SmCo28 materials are axially magnetized, their magnetic forces will exceed the allowable range, which will increase the seal wear. The increase in the inner diameter of the dynamic ring and the gap between the dynamic ring and the magnetic static ring causes a decrease in the magnetic force. The increase in temperature affects the magnetic properties of permanent magnetic material, which leads to the decline of magnetic force between the dynamic ring and the magnetic static ring. The increase in rotor speed leads to the acceleration of the fluctuation frequency of the magnetic force. Still, the maximum and minimum values of the magnetic force under different speeds remain unchanged, and the maximum fluctuation rate is less than 3%. According to the analysis results, the fitting formula of magnetic force calculation is presented by the orthogonal test and the least squares method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603129 | PMC |
http://dx.doi.org/10.1038/s41598-024-81165-9 | DOI Listing |
ACS Sens
January 2025
CAS Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China.
Flexible pressure sensors are pivotal in advancing artificial intelligence, the Internet of Things (IoT), and wearable technologies. While microstructuring the functional layer of these sensors effectively enhances their performance, current fabrication methods often require complex equipment and time-consuming processes. Herein, we present a novel magnetization-induced self-assembly method to develop a magnetically grown microneedle array as a dielectric layer for flexible capacitive pressure sensors.
View Article and Find Full Text PDFMater Today Bio
February 2025
State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China.
Natural teeth fulfill functional demands by their heterogeneity. The composition and hydroxyapatite (HAp) nanostructured orientation of enamel differ from those of dentin. However, mimicking analogous materials still exhibit a significant challenge.
View Article and Find Full Text PDFACS Omega
January 2025
Applied Chemistry and Environment Laboratory, Applied Bioorganic Chemistry Team, Faculty of Science, Ibn Zohr University, Agadir 80000, Morocco.
The goal of this study was to synthesize and evaluate new antimicrobial compounds. We specifically focused on the development of 2,5-disubstituted tetrazole derivatives containing the O-methyl-2,3-O-isopropylidene-(D)-ribofuranoside groups through N-alkylation reactions. The synthesized compounds were characterized using H and C nuclear magnetic resonance (NMR) spectroscopy.
View Article and Find Full Text PDFNat Astron
November 2024
NASA Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA USA.
The Voyager 2 flyby of Uranus in 1986 revealed an unusually oblique and off-centred magnetic field. This single in situ measurement has been the basis of our interpretation of Uranus's magnetosphere as the canonical extreme magnetosphere of the solar system; with inexplicably intense electron radiation belts and a severely plasma-depleted magnetosphere. However, the role of external forcing by the solar wind has rarely been considered in explaining these observations.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Institute for Special Environmental Biophysics, Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an 710100, Shaanxi, PR China; Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen 518063, PR China. Electronic address:
Magnetic nanoparticles effectively target drug delivery, contrast agents, biosensors, and more. Urchin-like magnetic nanoparticles (UMN) with abundant spike-like structures exhibit superior magneto-mechanical force to destroy tumor cells compared with other shapes of magnetic nanoparticles. However, when cell contents are released from tumor cells induced by magneto-mechanical force, they can act on surrounding tumor cells to facilitate tumor development.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!