A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of enoxaparin and argatroban by use of the novel viscoelastic coagulometer ClotPro. | LitMetric

Detection of enoxaparin and argatroban by use of the novel viscoelastic coagulometer ClotPro.

Sci Rep

Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Care Medicine, Medical University of Vienna, Währinger Gürtel 18-20, Wien, Vienna, 1090, Austria.

Published: November 2024

AI Article Synopsis

  • The study investigates point-of-care diagnostic tests for monitoring the anticoagulants enoxaparin and argatroban in critically ill patients who face risks of thrombosis and bleeding.
  • Blood samples from twelve healthy volunteers were used to evaluate the performance of the ClotPro viscoelastic coagulometer alongside traditional coagulation tests.
  • Results indicated that the RVV test for enoxaparin is not reliable, while the ECA test shows strong correlation and may be a better option for accurately detecting argatroban levels.

Article Abstract

Owing to the simultaneous increase in the risk of thrombosis and bleeding in critically ill patients, point-of-care-available diagnostic tests to guide parenteral anticoagulation are warranted. We evaluated the detection of enoxaparin and argatroban, two commonly used parenteral anticoagulants, using the novel ClotPro viscoelastic coagulometer. For this experimental in vitro study at a tertiary care academic center, blood samples were drawn from twelve (six female, six male) healthy volunteers without intake of antithrombotic medication and no history of hemostatic disorders. Blood samples were spiked with enoxaparin (IU.ml) and argatroban (µg.ml) at increasing concentrations ranging from 0 to 1. The ClotPro Russell's viper venom (RVV)-test and the ClotPro ecarin (ECA)-test clotting time were performed in parallel with conventional coagulation tests (anti-Xa activity, activated partial thromboplastin time, and diluted thrombin time). We observed a strong correlation between anti-Xa activity and the RVV-test clotting time (r = 0.88 (95% confidence interval (CI) 0.8-0.92; p < 0.001)). Although clotting time cutoff values of 71 and 145 s provided high sensitivity and specificity for detecting anti-Xa activity of ≤ 0.1 and ≥0.6 IU.ml, we found a poor performance at both high and low concentrations. The ECA-test clotting time revealed a very strong correlation with activated partial thromboplastin time (r = 0.96 (95% CI 0.93-0.97; p < 0.001)) and diluted thrombin time (r = 0.97 (95% CI 0.96-0.98; p < 0.001)). The clotting time cutoff values of 86 and 298-431 s provided high sensitivity and specificity for detecting diluted thrombin time values ≤ 0.1 and 0.5-1 µg.ml. Our results suggest that the RVV test is an unreliable method for monitoring enoxaparin treatment, whereas the ECA-test might be an accurate point-of-care alternative for detecting argatroban concentration with potential advantages over standard coagulation tests in terms of point-of-care applicability and turnaround time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603016PMC
http://dx.doi.org/10.1038/s41598-024-81396-wDOI Listing

Publication Analysis

Top Keywords

detection enoxaparin
8
enoxaparin argatroban
8
viscoelastic coagulometer
8
blood samples
8
clotting time
8
anti-xa activity
8
argatroban novel
4
novel viscoelastic
4
clotpro
4
coagulometer clotpro
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!