Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Lower eyelid blepharoplasty is one of the most popular aesthetic procedures. Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, particularly in Asian skin types. We compared the Colorado needle electrocautery (pure-cutting mode) versus the traditional scalpel in terms of efficacy, complications, and cosmetic outcomes.
Methods: A prospective intraindividual randomized controlled trial was conducted to compare the efficacy of Colorado needle electrocautery and scalpel in lower blepharoplasty. The study outcomes were scar quality at different times until 1 year postoperatively, bleeding during incision, and postoperative ecchymosis. Scar quality was evaluated using 3 standard scar ratings: the Vancouver Scar Scale, Patient and Observer Scar Assessment Scale, and Hollander wound evaluation scale.
Results: The study included 25 patients, and the electrocautery side had less blood loss during incision than the scalpel side (2.6 ± 0.65 versus 5.28 ± 0.68 sticks; < 0.001). The electrocautery side had less postoperative ecchymosis ( < 0.001); however, 1-year scar quality was not statistically significant between the groups.
Conclusions: Colorado needle electrocautery pure-cutting mode can be an alternative to the traditional scalpel for lower eyelid blepharoplasty skin incision because of long-term scar quality. Electrocautery also has hemostatic benefits, leading to a decrease in intraoperative and postoperative bleeding.