Fibrinogen-Induced Regeneration Sealing Technique (F.I.R.S.T.): A Retrospective Clinical Study on 105 Implants with a 3-7-Year Follow-Up.

J Clin Med

Department of Head and Neck Surgery and Maxillofacial Surgery, Tel-Aviv Sourasky Medical Center, School of Medicine, Tel Aviv University, 6 Weizmann Street, Tel-Aviv 6423906, Israel.

Published: November 2024

The primary aim of this retrospective clinical study was to assess the success and bone gain achieved by using the Fibrinogen-Induced Regeneration Sealing Technique (F.I.R.S.T.) in different indications. In this single-center retrospective clinical study, F.I.R.S.T. was performed in the following indications: alveolar ridge preservation (ARP), immediate implant placement, and horizontal and vertical guided bone regeneration (GBR) with simultaneous dental implant placement. F.I.R.S.T. is a modified approach to GBR characterized by the application of a porcine cortical lamina, as a long-term resorbable bone barrier to cover the bone defect, and a fibrin sealant for easy adaptation of the xenogenic bone graft material and the fixation of the collagenic bone barrier. Patients with uncontrolled systemic diseases, medications, or diseases that may alter bone metabolism; local inflammation; poor oral hygiene; and heavy smoking were excluded from this study. Horizontal and vertical bone gain (HBG and VBG) were measured by comparing postoperative and preoperative cone beam computed tomography (CBCT) reconstructions. Patients were recalled for controls and oral hygiene treatment every 6 months. Altogether, 62 patients (27 male, 35 female, age 63.73 ± 12.95 years) were included in this study, and 105 implants were placed. Six implants failed during the 50.67 ± 22.18-month-long follow-up. Cumulative implant survival throughout the groups was 94.29 %. In the immediate implant group, HBG was 0.86 mm (range: -0.75-8.19 mm) at the 2 mm subcrestal level, while VBG was 0.87 ± 1.21 mm. In the ARP group, HBG was 0.51 mm (range: -0.29-3.90 mm) at the 2 mm subcrestal level, while VBG was -0.16 mm (range: -0.52-0.92 mm). In the horizontal GBR group, HBG was 2.91 mm (range: 1.24-8.10 mm) at the 2 mm subcrestal level. In the vertical GBR group, VBG was 4.15 mm (range: 3.00-10.41 mm). F.I.R.S.T. can be utilized successfully for bone augmentation. The vertical and horizontal bone gains achieved through F.I.R.S.T. allow for implant placement with adequate bone width on both the vestibular and oral aspects of the implant.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11594896PMC
http://dx.doi.org/10.3390/jcm13226916DOI Listing

Publication Analysis

Top Keywords

retrospective clinical
12
clinical study
12
implant placement
12
group hbg
12
subcrestal level
12
bone
11
fibrinogen-induced regeneration
8
regeneration sealing
8
sealing technique
8
study 105
8

Similar Publications

A 3-dimensional comparative assessment of the dentoskeletal effects of clear aligners vs temporary skeletal anchorage device-assisted posterior intrusion in adolescents with anterior open bite: A single-center, retrospective, cohort study.

Am J Orthod Dentofacial Orthop

December 2024

Discipline of Orthodontics, School of Dentistry, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia; Department of Orthodontics, Sydney Dental Hospital, Sydney Local Health District, Sydney, Australia; Division of Orthodontics, University Clinics of Dental Medicine, Faculty of Medicine, University of Geneva, Geneva, Switzerland. Electronic address:

Introduction: The dentoskeletal effects of clear aligner treatment (CAT) with Invisalign vs temporary skeletal anchorage device-anchored Sydney intrusion spring (SIS) were compared in consecutively treated growing patients with anterior open bite using cone-beam computed tomography scans.

Methods: Fifteen adolescents treated exclusively with Invisalign, and 14 with SIS (first-phase treatment) were assessed retrospectively. Rigid-wise, voxel-based registration of pretreatment and posttreatment cone-beam computed tomography scans were performed using the anterior cranial base, maxillary plane, and mandibular body as reference regions.

View Article and Find Full Text PDF

Constant antigenic changes, new variants and easy transmission of SARS-CoV-2 virus should acquire greater zoonotic attention and need to remain alert. In this retrospective study the aim was to analyze seropositivity to SARS-CoV-2 in dogs by commercial ELISA. The Virus neutralization test (VNT) was modified for the purpose of confirmation of SARS-CoV-2 antibodies in ELISA-positive dog sera.

View Article and Find Full Text PDF

Cardiovascular problems in rabbits in reference to hypothyroidism - a four-year retrospective study.

Pol J Vet Sci

December 2024

Department of Epizootiology and the Clinic of Infectious Diseases, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Głęboka 30, 20-612 Lublin, Poland.

The effects of T4 are mainly manifested by positive ino- and chronotropism. The syndrome accompanying hypothyroidism in rabbits (impaired myocardial contractility and reduced ejection capacity) is caused by a deficiency of thyroid hormones - especially T4. The study group consisted of a total of 41 animals: 15 males and 26 females, ranging in age from 2 months to 8 years, with echocardiogram showing reduced fractional shortening (<30%), with normal results of heamatological and biochemical tests.

View Article and Find Full Text PDF

Purpose: This study aims to investigate the indications and therapeutic efficacy of flow-diverting stents (FDSs) in the management of extracranial carotid artery aneurysms (ECAAs) and dissections.

Methods: A retrospective analysis was conducted on 18 patients treated for ECAAs with an FDS between 2010 and 2024. Patient demographics, aneurysm characteristics, procedural details, and clinical and radiologic follow-up outcomes were extracted from medical records.

View Article and Find Full Text PDF

Background: Cardiac computed tomography imaging with contrast is being used increasingly to image left atrial appendage occlusion (LAAO) devices. Contrast flow across a device, also known as a transfabric leak (TFL), may indicate a lack of complete LAAO-device endothelialization. The data on the rate, predictors, and clinical events associated with TFL are limited.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!