The actuator is a critical component of the micromanipulator. By utilizing the properties of expansion and contraction, the piezoelectric actuator enables the manipulator to handle and grasp miniature objects during micromanipulation. However, in piezoelectric ceramic disc actuators with conventional surface electrode configurations, the actuating force generated in the radial direction is relatively limited. When used as the actuation element of the manipulator, achieving regulation over a wide range of operating strokes becomes challenging. Therefore, altering the electrode structure is necessary to generate a greater radial force, thus enhancing the positioning and grasping capabilities of the operating arm. This paper investigates a piezoelectric actuator with interdigitated spiral electrodes, featuring a constant pitch between adjacent electrodes. The radial force was tested under mechanical clamping conditions, and the influence of the electrical signal was examined. The characteristics of the electrode structure were described, and the working principles of the piezoelectric actuators were analyzed. Theoretical equations were derived for the macroscopic characterization of the radial clamping force of the actuator, based on the piezoelectric constitutive equation, geometric principles, and Bond matrix transformation relationships. A finite element model was developed, reflecting the features of the electrode structure, and finite element simulations were employed to verify the theoretical equations for radial force. To prepare the samples, encircled interdigitated spiral electrode lines were printed on the PZT-52 piezoelectric ceramic disc using a screen printing method. The clamping force experimental platform was established, and experiments on the clamping radial force were conducted with electrical signals of varying waveforms, frequencies, and voltages. The experimental results show that the piezoelectric ceramic disc actuator with an interdigitated spiral electrode line structure, when excited by a stable sine wave operating at 200 V and 0.2 Hz, generated a peak force of 0.37 N. It was 1.76 times greater than that produced by a previously utilized piezoelectric disc with conventional electrode structures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596320PMC
http://dx.doi.org/10.3390/mi15111378DOI Listing

Publication Analysis

Top Keywords

radial force
20
interdigitated spiral
16
electrode structure
16
piezoelectric actuator
12
actuator interdigitated
12
piezoelectric ceramic
12
ceramic disc
12
force
9
piezoelectric
9
spiral electrodes
8

Similar Publications

Machine learning helps reveal key factors affecting tire wear particulate matter emissions.

Environ Int

December 2024

Tianjin Key Laboratory of Urban Transport Emission Research, College of Environmental Science and Engineering, Nankai University, 1st Floor, Nankai University Press, No.94 weijin Road, Nankai District, Tianjin 300071, China. Electronic address:

Tire wear particles (TWPs) are generated with every rotation of the tire. However, obtaining TWPs under real driving conditions and revealing key factors affecting TWPs are challenging. In this study, we obtained a TWPs dataset by simulating tire wear process under real driving conditions using a tire wear simulator and custom-designed test conditions.

View Article and Find Full Text PDF

The modification of Pt surfaces with organic compounds like melamine enhances oxygen reduction reaction activity and catalyst durability. Through first-principles free energy calculations utilizing thermodynamic integration and finite-temperature molecular dynamics, enhanced by machine learning force fields for efficient sampling of nanosecond-scale interfacial water fluctuations and incorporating corrections to accurately reproduce first-principles free energies, we demonstrate that melamine destabilizes OH adsorbates, facilitating their removal and enhancing catalytic activity. Unlike alloys, where OH destabilization is driven by changes in electronic structure and surface strain, melamine disrupts hydrogen bonding between OH and interfacial water.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to determine if there were differences in the tendon forces needed to cause wrist motion and in the passive range of wrist motion following total wrist replacement (TWR) using a contemporary arthroplasty design.

Methods: Eight fresh frozen cadaver arms were moved through five different wrist motions using a wrist joint simulator before and after the insertion of a TWR. Changes in the peak tendon forces and wrist range of motion were compared.

View Article and Find Full Text PDF

Introduction: Dynamic modulation of grip occurs mainly within the major structures of the brain stem, in parallel with cortical control. This basic, but fundamental level of the brain, is robust to ill-formed feedback and to be useful, it may not require all the perceptual information of feedback we are consciously aware. This makes it viable candidate for using peripheral nerve stimulation (PNS), a form of tactile feedback that conveys intensity and location information of touch well but does not currently reproduce other qualities of natural touch.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the biomechanical properties of SutureTape as an alternative technique for arthrodesis of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint arthrodesis when compared with surgical steel wire.

Methods: A total of 32 fingers (index, long, ring, and small) from two matched pair cadaveric hands were used. K-wire and surgical steel wire were used for MCP and PIP joint arthrodesis of the control group (group I), whereas K-wire and SutureTape were used for the experimental group (group II).

View Article and Find Full Text PDF