Fabrication of Radial Array Transducers Using 1-3 Composite via a Bending and Superposition Technique. | LitMetric

AI Article Synopsis

  • * A specialized flexible circuit board was created to connect and actuate all transducer elements, using a bending-and-superposition manufacturing method that effectively binds the components.
  • * The transducer demonstrated impressive performance metrics, including a center frequency of 2.72 MHz, a bandwidth of 36%, and low crosstalk levels, showcasing the potential of this fabrication technique and material combination.

Article Abstract

Piezoelectric composite materials, combining the advantages of both piezoelectric materials and polymers, have been extensively used in ultrasonic transducers. However, the pitch size of radial array ultrasonic transducers normally exceeds one wavelength, which limits their performance. In order to minimize grating lobes of current radial transducers and then increase their imaging resolution, a 2.5 MHz 1-3 composite radial array transducer with 64 elements and 600 μm pitch was designed and fabricated by combining flexible circuit board and using a bending-and-superposition method. All the array elements were connected and actuated via the customized circuit board which is thin and soft. The kerf size is set to be 1/3 wavelength. PZT-5H/epoxy 1-3 composite was used as an active material because it exhibits an ultrahigh electromechanical coupling coefficient ( = 0.74), a very low mechanical quality factor ( = 11), and relatively low acoustic impedance ( = 13.43 MRayls). The developed radial array transducer exhibited a center frequency of 2.72 MHz, an average -6 dB bandwidth of 36%, an insertion loss of 31.86 dB, and a crosstalk of -26.56 dB between the adjacent elements near the center frequency. These results indicate that the bending-and-superposition method is an effective way to fabricate radial array transducers by binding flexible circuit boards. Furthermore, the utilization of tailored flexible circuitry boards presents an effective approach for realizing reductions in crosstalk level (CTL).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596718PMC
http://dx.doi.org/10.3390/mi15111363DOI Listing

Publication Analysis

Top Keywords

radial array
20
1-3 composite
12
array transducers
8
ultrasonic transducers
8
array transducer
8
flexible circuit
8
circuit board
8
bending-and-superposition method
8
center frequency
8
array
6

Similar Publications

Taking into account phase-polarization interactions is crucial for the formation of spatially structured laser beams. The effects that arise in this context can lead to the modulation of individual field components and the transformation of the overall light field. In this study, we investigate the impact of phase and polarization distributions with radial dependencies in polar coordinates on the longitudinal component of laser beams passing through a transmissive spatial light modulator (SLM) based on twisted nematic liquid crystals.

View Article and Find Full Text PDF

Motile cilia are ancient, evolutionarily conserved organelles whose dysfunction underlies motile ciliopathies, a broad class of human diseases. Motile cilia contain a myriad of different proteins that assemble into an array of distinct machines, and understanding the interactions and functional hierarchies among them presents an important challenge. Here, we defined the protein interactome of motile axonemes using cross-linking mass spectrometry in Tetrahymena thermophila.

View Article and Find Full Text PDF

This study demonstrates high volume rate bistatic 3-D vascular strain imaging, to overcome well-known challenges caused by the anisotropic resolution and contrast inherent to ultrasound imaging. Approach. Using two synchronized 32x32 element matrix arrays (3.

View Article and Find Full Text PDF

Carbon nanofibers show the advantages of scale effects on electrical and mechanical properties for applications such as aerospace, automotive, and energy, but have to confront the challenge of maximizing the role of scale effects. Here, a method of additive nanostructuring and carbonization of polyacrylonitrile (PAN) jetting for the nano-forming of carbon fibers is developed by understanding the electrostatic submicro-initiation of a PAN jetting, altering the microstructure of PAN-based jetting fibers at the nanoscale and implementing subsequent carbonization of PAN jetting nanofiber. Using this method of additive nanostructuring and carbonization in combination with the radial distribution pattern of shear stress, we find that the conformation of some molecular chains inside the PAN nanofibers is transformed into the zigzag conformation.

View Article and Find Full Text PDF

The flow dynamics of low-yield horizontal wells demonstrate considerable complexity and unpredictability, chiefly attributable to the structural attributes of the wellbore and the interplay of gas-water two-phase flow. In horizontal wellbores, precisely predicting flow patterns using conventional approaches is often problematic. Consequently, accurate monitoring and analysis of water holdup in gas-water two-phase flows are essential.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!