: Anatomical variations in the biceps brachii muscle (BBM) are extremely frequent, leading to developmental and clinical implications. We studied the topography of the BBM and analyzed its correlations with other structures in the brachial region. A total of 103 cadaveric upper extremities were dissected. The length of the upper extremities was utilized as a reference line. The origin and insertion of the BBM, the coracobrachialis muscle (CBM), and the related neurovascular system were evaluated. : Each variable was calculated as a percentile and compared according to the presence of the considered variation; in particular, a supernumerary head of the BBM was found in 12/103 (11.65%) of upper extremities and was associated with a longer upper limb (506.25 ± 32.55 mm vs. 484.27 ± 30.41 mm, = 0.022). When the variables were standardized by the length of the upper limb, the accessory head of the BBM was associated with the distal insertion point of the CBM (28.18 ± 3.54% vs. 30.59 ± 2.94%, = 0.011) and BBM length (55.11 ± 2.17% vs. 58.18 ± 3.72%, = 0.006). Other variables did not present significant differences with respect to the presence of the supernumerary head of the BBM. BBM variations may affect the topography of other structures, such as the length of the upper extremities, insertion of the CBM, and length of the BBM. Further studies are required to elucidate its clinical implications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596292 | PMC |
http://dx.doi.org/10.3390/medicina60111726 | DOI Listing |
Acta Chir Orthop Traumatol Cech
January 2025
University of Mersin, School of Medicine, Department of Orthopaedics and Traumatology, Division of Hand Surgery, Mersin, Turkey.
Purpose Of The Study: The aim of this study to evaluate the subjective and objective results of Extensor indicis proprius (EIP) to extensor pollicis longus (EPL) transfer with an emphasis on donor site morbidity.
Material And Methods: 17 patients (59% men, 41% women) who underwent EIP-EPL transfer were retrospectively analyzed. The mean age was 43 (9-64) years, and the mean follow-up was 72 (19-124) months.
J Exerc Rehabil
December 2024
Institute of Digital Anti-Aging Healthcare, Inje University, Gimhae, Korea.
This study aimed to investigate the effects of a foam roller-based combined exercise program on functional fitness, balance ability, and gait in women aged 65 years and older. Using a 2×2 mixed design, the study compared variables measured before and after a 6-week foam roller-based combined exercise program. A total of 32 old women were randomly assigned to either the foam roller-based exercise group or the control group.
View Article and Find Full Text PDFCureus
December 2024
Department of Rehabilitation, Musashigaoka Hospital, Kumamoto, JPN.
Gait asymmetry in post-stroke patients is an important gait characteristic that is associated with their balance control, inefficiency, and risks of musculoskeletal injury to the non-paretic lower limb and falling. Unfortunately, most stroke patients retain an asymmetrical gait pattern, even though their gait independence and gait speed improve. We describe the clinical course of a subacute stroke patient who achieved a symmetrical gait at discharge after undergoing both gait training with orthoses and robot-assisted gait training from the early intervention phase.
View Article and Find Full Text PDFCureus
December 2024
Orthopedic Department, Laiko General Hospital of Athens, Athens, GRC.
Carpometacarpal (CMC) joint fractures-dislocations are rare due to the complex structure of the carpal bones and strong ligamentous support; while the clinical image is usually "noisy," they present significant management challenges due to the unstable nature of the injury. These injuries are typically caused by high-energy trauma and frequently result in dorsal dislocations. Treatment requires a careful balance between the immobilization and surgical restoration of the anatomical alignment to prevent complications.
View Article and Find Full Text PDFJ Cosmet Dermatol
January 2025
Cosmetic Science, Institute of Biochemistry and Molecular Biology, University of Hamburg, Hamburg, Germany.
Background: The concept of "skin quality" (SQ) has gained widespread attention, with a recent international consensus defining it and outlining four "emergent perceptual categories" (EPCs), each accompanied by specific parameters and associated measurement methods. No research has confirmed whether the parameters linked to these EPCs vary objectively with age. This gap in data is significant, as understanding how these parameters correlate with age could be essential for creating an objective, age-adjusted classification of SQ.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!