In the case of a weak signal from a photon counting lidar and strong noise from the solar background, the signal is completely submerged by noise, potentially resulting in the appearance of multiple peaks in the denoising algorithm of photon counting entropy. Consequently, a clear distinction between the signal and noise may become challenging, leading to significant fluctuation in the ranging error. To solve this problem, this paper proposes an improved offset parameter optimization algorithm under the framework of photon counting entropy, aiming to effectively eliminate peak interference caused by noise and enhancing ranging accuracy. The algorithm includes two aspects. First, we introduce the solar irradiance prediction of an MLP network and least squares linear conversion to accurately estimate the noise rate of the solar background noise. Then, we propose the offset parameter optimization method to effectively mitigate the interference caused by noise. In simulation and experimental analyses, the ranging error of our proposed method is within 5 and 30 cm, respectively. Compared with the denoising method of photon counting entropy, the average ranging error is increased by 81.99% and 73.76%. Furthermore, compared to other anti-noise methods, it exhibits superior ranging capability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11592563PMC
http://dx.doi.org/10.3390/e26110934DOI Listing

Publication Analysis

Top Keywords

photon counting
20
offset parameter
12
parameter optimization
12
counting entropy
12
ranging error
12
optimization algorithm
8
counting lidar
8
solar background
8
interference caused
8
caused noise
8

Similar Publications

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

Sub-millikelvin-resolved superconducting nanowire single-photon detector operates with sub-pW infrared radiation power.

Natl Sci Rev

January 2025

Research Institute of Superconductor Electronics, School of Electronic Science and Engineering, Nanjing University, Nanjing 210023, China.

The noise equivalent temperature difference (NETD) indicates the minimum temperature difference resolvable by using an infrared detector. The lower the NETD, the better the sensor can register small temperature differences. In this work, we proposed a strategy to achieve a high temperature resolution using a superconducting nanowire single-photon detector (SNSPD) with ultra-high sensitivity.

View Article and Find Full Text PDF

Objectives: To compare a novel photon-counting sensor, two CBCT protocols and two CMOS sensors on the detection of gaps between a gutta-percha cone and root canal walls.

Methods: Twenty-five mandibular incisors were prepared to 45/.04 (size/taper) at working length.

View Article and Find Full Text PDF

Large-scale quantum networks require dynamic and resource-efficient solutions to reduce system complexity with maintained security and performance to support growing number of users over large distances. Current encoding schemes including time-bin, polarization, and orbital angular momentum, suffer from the lack of reconfigurability and thus scalability issues. Here, we demonstrate the first-time implementation of frequency-bin-encoded entanglement-based quantum key distribution and a reconfigurable distribution of entanglement using frequency-bin encoding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!