A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

From Mechanical Machining Technology: A New Solution That Integrates Blades to the Implant to Control the Stress to the Peri-Implant Cortical Bone. | LitMetric

Background: To prevent excessive compression of the cortical layer, which can lead to marginal bone loss, various companies have introduced specialized drills. However, these drills often lack the necessary precision, as the operator's hand may neither be stable enough to prevent ovalization and over-widening nor precise enough to maintain coaxial alignment. Therefore, the aim of this study was to develop a device capable of achieving calibrated cortical preparation in terms of both dimension and coaxiality.

Methods: A machining technology based on drilling principles was employed to create the device.

Results: Nine blades were incorporated between the transmucosal neck and the implant threads, enabling the blades to cut the cortical bone coaxially during the implant insertion process.

Conclusions: The primary goal of this study was to develop an implant capable of achieving calibrated cortical bone preparation, ensuring both precise dimensional control and coaxial alignment. This design incorporates integrated blades that allow for controlled cortical decompression, helping to manage radial compressive stresses during implant placement. Although the experimental studies cited were conducted independently of this research, they validate the functional efficacy of this implant design, demonstrating its ability to promote osseointegration and preserve marginal bone. The results suggest that this implant configuration holds the potential for improving clinical outcomes, particularly in cases where bone quality or density poses challenges to implant stability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11591490PMC
http://dx.doi.org/10.3390/bioengineering11111077DOI Listing

Publication Analysis

Top Keywords

cortical bone
12
machining technology
8
implant
8
marginal bone
8
coaxial alignment
8
study develop
8
capable achieving
8
achieving calibrated
8
calibrated cortical
8
cortical
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!