Determination of representative elementary surface for accurately measuring radon exhalation rate in masonry wall.

J Hazard Mater

School of Resources Environment and Safety Engineering, University of South China, Hengyang 421001, China.

Published: January 2025

AI Article Synopsis

  • * Different materials, such as bricks and cement mortar, have varying radon exhalation rates, necessitating careful consideration of measurement methods and apparatus used.
  • * A Computed Fluid Dynamics (CFD) study found that selecting a representative elementary surface (RES) for measurement can lead to more accurate results in assessing radon exhalation from masonry walls.

Article Abstract

The average radon exhalation rate of the building wall surface is a key factor affecting indoor radon concentration, and its accurate measurement is of great significance for the evaluation and design of radon protection for walls. The main layer of the masonry walls is composed of bricks and bonded cement mortar. Due to the possible differences in radon exhalation rates from brick surfaces and cement mortar joints. General methods for measuring radon exhalation rate of the wall (such as the closed-loop method, the opened-loop method and the local static collection method) all involve the use of radon collection hoods. However, the measurement results of radon exhalation rate are significantly affected by the position and size of the radon collection hood covering the wall surface. Therefore, the Computational Fluid Dynamics (CFD) method was used to study the radon exhalation rules on the surface of masonry wall under diffusion and seepage-diffusion conditions, respectively. The simulation results show that the radon exhalation rates on the brick surfaces and cement mortar joints of masonry walls are different, and a representative elementary surface (RES) should be selected when accurately measuring the radon exhalation rate of the wall surface. It is worth noting that the shape of the RES is not restricted, and the representative surface for measuring radon exhalation rate is not unique; it can be an integer multiple surface of RES area. Furthermore, experiments have confirmed the accuracy and effectiveness of the determined RES. The proposed RES achieves accurate measurement of the average radon exhalation rate of walls by integrating the radon exhalation rates at the joints between bricks and cement mortar.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2024.136630DOI Listing

Publication Analysis

Top Keywords

radon exhalation
44
exhalation rate
28
measuring radon
16
cement mortar
16
radon
15
wall surface
12
exhalation rates
12
exhalation
11
representative elementary
8
surface
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!