Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Inside hospitals, there is a trend of increasing levels of air pollutants. However, only the indoor air quality in operating theaters is carefully monitored. Therefore, we set the goal of this study to evaluate the indoor air quality in areas of an orthopedics department and to compare the indoor air quality indices that characterize these areas. We used a monitoring system based on the Internet of Things with uRADMonitor model A3 sensors, with which we prospectively measured indoor air quality in the facilities of the orthopedic emergency hospital of Targu Mures in Romania, between 1 February 2023, and 31 January 2024. The primary target pollutants investigated in the emergency room, outpatient room and ward were carbon dioxide (CO), nitrogen dioxide (NO), volatile organic compounds (VOCs) and particles with a diameter smaller than 2.5 μm (PM2.5). We compared the effectiveness of the intervention for emergency rooms where air purifiers were working or not. The concentrations of CO, VOCs and PM2.5 were significantly higher in the emergency room than in the outpatient room or ward. The indoor air quality was worst in winter, when the CO, NO and VOC concentrations were at their highest. Air purifiers can help reduce the concentration of PM2.5 in emergency rooms. Medical staff and patients in orthopedic hospitals, especially in emergency rooms, are frequently exposed to polluted ambient air, which can affect their health. Orthopedic medical practice guidelines should address issues relating to the protection of personnel through the application of measures to improve indoor air quality.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11598109 | PMC |
http://dx.doi.org/10.3390/toxics12110815 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!