AI Article Synopsis

  • * The size and shape of tantalum granules vary significantly between two commonly used NAGLEMs, ONYX and SQUID, influencing their effectiveness; ONYX granules are larger and irregular, while SQUID granules are smaller and spherical.
  • * In clinical comparisons, SQUID 18 displayed superior penetration in dural vessels during embolization in older patients, suggesting that both the viscosity of NAGLEMs and the physical characteristics of tantalum granules are crucial for their performance.

Article Abstract

Tantalum powder is included in the composition of Non-Adhesive Gel-like Embolic Materials (NAGLEMs) for X-ray opacity. The duration of X-ray opacity during embolization is primarily associated with the particle size, which differs in the most used NAGLEMs-ONYX (Medtronic) and SQUID (Balt). NAGLEMs are widely used for the embolization of branches of the middle meningeal artery (MMA) in patients with chronic subdural hematomas (CSDHs). Considering the size (5-15 microns) of the target dural vessels, we assumed that not only the viscosity of NAGLEMs, but also the size and shape of tantalum granules may be important for the penetration of these gel-like embolic agents and determine their behavior. A notable discrepancy in size was observed. The medium-sized granules in the SQUID 18 sample (0.443 ± 0.086 microns, M ± SD) were found to be approximately ten times smaller than the tantalum granules in the ONYX 18 sample (5.2 ± 0.33 microns, M ± SD).Tantalum granules in SQUID 18 have a regular spherical shape; in ONYX 18 they have an irregular angular shape. When comparing the behavior of gel-like embolic agents of the same viscosity during MMA embolization in patients with CSDHs (an average age of 62.2 ± 14.3 years) in the group where SQUID 18 ( = 8) was used, the gel-like embolic agent in dural vessels demonstrated significantly greater penetration ability compared with the group where ONYX 18 ( = 8) was used. Accordingly, not only the viscosity of NAGLEMs, but also the size and shape of tantalum granules can have a significant effect on the penetration ability of gel compositions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11595222PMC
http://dx.doi.org/10.3390/jfb15110319DOI Listing

Publication Analysis

Top Keywords

gel-like embolic
20
dural vessels
12
tantalum granules
12
non-adhesive gel-like
8
embolic materials
8
tantalum powder
8
x-ray opacity
8
viscosity naglems
8
naglems size
8
size shape
8

Similar Publications

Article Synopsis
  • * The size and shape of tantalum granules vary significantly between two commonly used NAGLEMs, ONYX and SQUID, influencing their effectiveness; ONYX granules are larger and irregular, while SQUID granules are smaller and spherical.
  • * In clinical comparisons, SQUID 18 displayed superior penetration in dural vessels during embolization in older patients, suggesting that both the viscosity of NAGLEMs and the physical characteristics of tantalum granules are crucial for their performance.
View Article and Find Full Text PDF

Purpose: Autologous serum tears (ASTs) are produced from serum obtained by blood draw and used to treat severe dry eye diseases. Multiple cases of failed AST production occurred due to serum becoming a solidified, gel-like substance after centrifugation. The aim of this study was to identify risk factors associated with inability to compound AST.

View Article and Find Full Text PDF

Objectives: The use of non-adhesive gel-like embolic materials (NAGLEMs) in the endovascular treatment of hypervascularized formations in the head and neck is gaining in popularity because of a number of important characteristics involved. Their primary benefits are their capacity to penetrate diseased vasculature, effectively distribute, and, most importantly, remain controllable during the process. We reviewed the literature and evaluated the results of using NAGLEMs in comparison to other embolizing substances (namely, coils, glue, and particles) as alternative embolizing agents for patients receiving care at our clinic.

View Article and Find Full Text PDF

Objectives: Tract embolization has been performed to prevent bleeding after trans-organ puncture. This study evaluated clinical outcomes of tract embolization using a gel-like radiopaque material comprising two sheets of gelatin sponge and 3 mL of contrast agent, and experimentally confirmed its viscosity and hemostatic efficacy.

Methods: Three study phases were planned.

View Article and Find Full Text PDF

Objectives: Thermosensitive chitosan/glycerophosphate (C/GP) solutions exhibiting sol-gel transition around body temperature were prepared to develop a class of injectable hydrogel platforms for the imaging and loco-regional treatment of hepatocellular carcinoma (HCC). Indocyanine green (ICG) was loaded in the thermosensitive solutions in order to assess their potential for the detection of tumor nodules by fluorescence.

Methods: The gel formation of these formulations as well as their gelling time, injectability, compactness and resistance of gel structure, gelling temperature, storage conditions, biodegradability, and in vitro dye release behavior were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!