A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigating the Potential of X-Ray-Based Cancer Treatment Equipment for the Sterile Insect Technique in Control Programs. | LitMetric

Investigating the Potential of X-Ray-Based Cancer Treatment Equipment for the Sterile Insect Technique in Control Programs.

Insects

Department of Pathogen Biology, Anhui Province Key Laboratory of Zoonoses, The Provincial Key Laboratory of Zoonoses of High Institutions in Anhui, School of Basic Medical Sciences, Anhui Medical University, Hefei 230032, China.

Published: November 2024

The sterile insect technique (SIT) stands as an eco-friendly approach for mosquito control, but it is impeded by the limited availability of γ-ray radiation source. This research sought to investigate a different radiation source-the Varian Clinac 23EX linear accelerator, which is frequently used for X-ray therapy in cancer treatment. Evaluation parameters including emergence rate, average survival time, induced sterility (IS), male mating competitiveness of irradiated males and fecundity (the number of eggs per female per batch), and the egg hatch rate of females mated with irradiated males were assessed to gauge the application potential of this cancer treatment equipment in the realm of the SIT. The results indicated that X-rays from radiation therapy equipment can effectively suppress the hatch rate of offspring mosquitoes without adversely affecting the emergence rate of irradiated males or the fecundity of females. In addition, at an X-ray dose of 60 Gy, the induced sterility in was comparable to the sterility induced by 40 Gy of γ-rays with both treatments resulting in 99.6% sterility. Interestingly, when a release ratio of 7:1 (irradiated males:unirradiated males) was used to competitively mate with females, the IS results resulted by 60 Gy X-rays and 40 Gy γ-rays were still at 70.3% and 73.7%, respectively. In conclusion, the results underscored the potential of the Varian Clinac 23EX linear accelerator as an X-ray source in SIT research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11594760PMC
http://dx.doi.org/10.3390/insects15110898DOI Listing

Publication Analysis

Top Keywords

cancer treatment
12
irradiated males
12
treatment equipment
8
sterile insect
8
insect technique
8
varian clinac
8
clinac 23ex
8
23ex linear
8
linear accelerator
8
emergence rate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!