Background: Corneal endothelium is responsible for maintaining cornea transparency by pumping fluid out of the stroma to prevent the development of corneal edema which leads to blurring of vision.
Purpose: The study aims to investigate the corneal endothelial cell density and morphology in young myopic patients wearing disposable soft contact lenses (SLC) using a non-contact specular biomicroscope.
Methods: A cross-sectional comparative study was conducted at Qassim University's optometry clinics from February to July 2024 in 100 healthy myopic patients, including 100 eyes wearing disposable soft contact lenses and 100 eyes wearing spectacle correction as control group. Clinical examinations included assessment of refractive error via autorefractometer and visual acuity via projector vision chart. Non-contact specular biomicroscope imaging was used to gather data on corneal endothelial cell density and morphology. Data were analyzed using SPSS v 25 (IBM Corp., Armonk, NY, USA).
Results: A total of 100 healthy myopic patients (200 eyes) participated in this study. Sixty-five (65%) were females and 35 (35%) were males. One hundred eyes wore SCL and 100 eyes were control group. The mean age was 22.14±1.92 years. The mean central corneal thickness (CCT) was 559.54±29.72.91 µm in the SCL group and 539.64±37.55 µm in the control group (p<0.001). The mean endothelial cell density (ECD) was 2628.03±238.66 cells/mm and 2589.29±254.49 cells/mm in SCL wearers and control group respectively (p=0.285). The mean coefficient variance (CV) was 35.44±6.07% in SCL wearers and 35.57±4.39% in non-wearers (p=0.023). The mean hexagonality (HEX) was 44.75±10.03% in SCL wearers and 44.83±8.40% in the control group (p=0.045). There was significant difference in cell number (p=0.018), polymegathism (p=0.002) and pleomorphism (p=0.002) between males and females in SCL wearers. Duration of SCL wear has negative correlation with ECD (r=-0.245; p=0.014) and polymegathism (-0.229; p=0.022). There was significant difference in CCT (p=0.005) and CV (p=0.027) in different types of SCL.
Conclusion: Wearing disposable soft contact lenses induces significant morphological changes in the corneal endothelium. It increases central corneal thickness and decreases degree of polymegathism and pleomorphism. The longer an individual wears contact lenses, the higher the likelihood decrease in endothelial cell density and polymegathism.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11582090 | PMC |
http://dx.doi.org/10.7759/cureus.74187 | DOI Listing |
Eye (Lond)
January 2025
Department of Translational Medicine, University of Ferrara, Ferrara, Italy.
Objectives: The aim of the study was to evaluate anatomical and functional outcomes of the Smaller-Incision New Generation Implantable Miniature Telescope (SING IMT™) in patients with bilateral advanced age-related macular degeneration (AMD).
Methods: This non-comparative retrospective single-surgeon interventional case series included patients with bilateral late-stage AMD who underwent cataract surgery and SING IMT™ implantation at the Sant'Anna University Hospital, University of Ferrara, Italy. The main outcome measures included corrected distance (CDVA) and near visual acuity (CNVA), endothelial cell loss (ECL), and incidence of complications.
Klin Monbl Augenheilkd
January 2025
Ophthalmology, Amsterdam UMC, Amsterdam, Netherlands.
Background: Refractory corneal edema is the foremost reason for endothelial corneal transplantation (EK) in the world. Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) offer good clinical outcomes. However, human donor tissue is limited in availability and has a complex logistical chain.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Pediatrics, Faculty of Medicine, Chulalongkorn University Bangkok, Bangkok, Thailand.
Purpose: To describe the demographic profile, clinical characteristics, and treatment trends of Fuchs endothelial corneal dystrophy (FECD) in Thai patients, reflecting the evolving landscape of corneal transplantation in this region.
Patients And Methods: This retrospective cohort study included 900 patients (1,743 eyes) diagnosed with FECD at a tertiary referral center in Thailand between January 2017 and June 2023. Demographic, clinical, and surgical data were analyzed, focusing on best-corrected visual acuity (BCVA), central corneal thickness (CCT), endothelial cell density (ECD), surgical interventions, and graft survival rate.
Am J Ophthalmol
January 2025
Piedmont Eye Center, Lynchburg, Virginia.
Purpose: To evaluate the intraocular pressure (IOP)-lowering effect and safety of up to two bimatoprost implant administrations versus selective laser trabeculoplasty (SLT).
Design: Phase 3 (Stage 2), randomized, 24-month, multicenter, patient- and efficacy evaluator-masked, paired-eye clinical trial (NCT02507687).
Participants: Patients (n=183) with open-angle glaucoma or ocular hypertension inadequately managed with topical IOP-lowering medication for reasons other than efficacy.
Int Immunopharmacol
January 2025
Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Ave, Wuhan, Hubei 430030 China. Electronic address:
Purpose: To explore the function of cyclopamine in corneal neovascularization and subsequent fibrosis after cornea alkali-burn injury.
Methods: In vivo, mice cornea were injured by NaOH, and then treated with cyclopamine, clodronate liposomes (CLO-LPS), and vehicle of cyclopamine separately by subconjunctival injections. Clinical features were observed and pathological characteristics were examined.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!