A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single-shot single-beam coherent Raman scattering thermometry based on optically induced air lasing. | LitMetric

Thermometric techniques with high accuracy, fast response and ease of implementation are desirable for the study of dynamic combustion environments, transient reacting flows, and non-equilibrium plasmas. Herein, single-shot single-beam coherent Raman scattering (SS-CRS) thermometry is developed, for the first time to our knowledge, by using air lasing as a probe. We show that the air-lasing-assisted CRS signal has a high signal-to-noise ratio enabling single-shot measurements at a 1 kHz repetition rate. The SS-CRS thermometry consistently exhibits precision of <2.3% at different temperatures, but the inaccuracy grows with the increase in temperature. The high measurement repeatability, 1 kHz acquisition rate and easy-to-implement single-beam scheme are achieved thanks to the unique temporal, spectral and spatial characteristics of air lasing. This work opens a novel avenue for high-speed CRS thermometry, holding tremendous potential for fast diagnostics of transient reacting flows and plasmas.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11586427PMC
http://dx.doi.org/10.1038/s41377-024-01598-9DOI Listing

Publication Analysis

Top Keywords

single-shot single-beam
8
single-beam coherent
8
coherent raman
8
raman scattering
8
air lasing
8
ss-crs thermometry
8
scattering thermometry
4
thermometry based
4
based optically
4
optically induced
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!