Enhancing indoor air quality and cardiopulmonary health in patients with asthma by photocatalytic oxidation and filters air cleaner.

J Hazard Mater

Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC; Institute of Environmental Engineering, College of Engineering, National Sun Yat-Sen University, Kaohsiung City, Taiwan, ROC; Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung City 807, Taiwan, ROC; Research Center for Precision Environmental Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC; Institute of Wildlife Conservation, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung City, Taiwan, ROC. Electronic address:

Published: November 2024

Background: Air purifiers can enhance indoor air quality and health outcomes, and studies have primarily focused on filters and particulate matter (PM) in households. Photocatalytic oxidation (PCO) is a promising technique for eliminating gaseous pollutants and bioaerosols. However, no field study was conducted in household. Therefore, this study evaluated the effects of the PCO and PCO + filters intervention on indoor air pollutants and cardiopulmonary endpoints in households.

Methods: A randomized, double-blind crossover clinical trial was conducted. Indoor air pollutants, including PM, bioaerosols, and gaseous pollutants and cardiopulmonary endpoints including lung function, fractional exhaled nitric oxide (FeNO), respiratory symptoms, and blood pressure were assessed before and after intervention.

Findings: This was the first study to evaluate the effects of PCO and PCO + filters interventions on indoor air pollutants and cardiopulmonary health in households. Indoor total volatile organic compounds (TVOC) and sulfur dioxides (SO) significantly reduced after PCO intervention, however, we also observed the significant reduction in percentage of predicted values of forced vital capacity (FVC%) and forced expiratory volume in 3 s (FEV%) and increased in FeNO after 13 days of PCO intervention. The PCO + filters intervention significantly reduced the levels of indoor PM, PM, PM, PM, total suspended particulate matter, ultrafine particles, airborne bacteria, fungi, endotoxin, mites, TVOC, nitrogen dioxide, and SO, and marginal reduction in carbon monoxide. However, indoor carbon dioxide significantly increased after PCO/PCO + filters intervention. As for cardiopulmonary health, FVC%, and FEV1 % marginally increased 7 days after the PCO + filters intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2024.136573DOI Listing

Publication Analysis

Top Keywords

indoor air
20
pco + filters
16
+ filters intervention
16
cardiopulmonary health
12
air pollutants
12
pollutants cardiopulmonary
12
pco
9
air quality
8
photocatalytic oxidation
8
particulate matter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!