Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Recent studies have highlighted the potential of earwax or cerumen, a non-conventional biomatrix, in volatilomics research as a valuable matrix for disease biomarker discovery. Despite that, there are still gaps in using non-conventional biomatrices in metabolomics research. In this sense, this study aimed to elucidate the main analytical factors involved in the extraction and analysis of volatile organic compounds (VOCs) in cerumen by headspace/gas chromatography-mass spectrometry (HS/GC-MS) using Design of Experiments (DoE) approaches. Furthermore, we present a repeatability study for the proposed method as a quality control process for cerumenomic assays. By applying factorial designs, it was possible to determine that the sample mass, splitless injector sampling time, headspace extraction time, headspace extraction temperature, injection volume, and vial volume were significant factors for the cerumen VOC analysis by HS/GC-MS. Throughout univariate and multivariate statistical approaches, we demonstrate that different analytical conditions lead to distinct chemical profiling of a sample. The most suitable analytical condition was determined after the optimization steps, and the proposed method's repeatability was evaluated by the metabolites coefficient variation (CV) calculation. Seventy-one earwax VOCs reached a CV considered adequate for untargeted metabolomics studies via GC-MS. In summary, this study describes a protocol for analysis optimization of a non-conventional biomatrix and also reports a quality control process in untargeted volatilomics assays using earwax. Our findings shed light on the potential of using earwax in volatolomic studies and establish analytical criteria to ensure quality in cerumenomic assays.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2024.465538 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!