Should we routinely measure patient quality of life after acute coronary syndrome?

Eur Heart J Qual Care Clin Outcomes

Columbia University School of Nursing, Columbia University Irving Medical Center, New York, NY, USA.

Published: November 2024

Download full-text PDF

Source
http://dx.doi.org/10.1093/ehjqcco/qcae098DOI Listing

Publication Analysis

Top Keywords

routinely measure
4
measure patient
4
patient quality
4
quality life
4
life acute
4
acute coronary
4
coronary syndrome?
4
routinely
1
patient
1
quality
1

Similar Publications

Background/aims: Certain sociodemographic groups are routinely underrepresented in clinical trials, limiting generalisability. Here, we describe the extent to which enriched enrolment approaches yielded a diverse trial population enriched for older age in a randomised controlled trial of a blood-based multi-cancer early detection test (NCT05611632).

Methods: Participants aged 50-77 years were recruited from eight Cancer Alliance regions in England.

View Article and Find Full Text PDF

SARS-CoV-2, the virus responsible for COVID-19, has undergone significant genetic evolution since its emergence in 2019. This study examines the genomic diversity of SARS-CoV-2 in Brazil after the worst phase of the pandemic, the wider adoption of routine vaccination, and the abolishment of other non-pharmacological preventive measures from July 2022 to July 2024 using 55,951 sequences retrieved from the GISAID database. The analysis focuses on the correlation between confirmed COVID-19 cases, sequencing efforts across Brazilian states, and the distribution and evolution of viral lineages.

View Article and Find Full Text PDF

Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography.

Pharmaceuticals (Basel)

December 2024

Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307 Dresden, Germany.

(1) : Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of Pb- and Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the Pb/Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) : The routine alpha detection on thin-layer chromatograms (TLC) of Pb- and Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) : For Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken.

View Article and Find Full Text PDF

Risk Factors Associated with Hemoparasites in Dual-Purpose Cattle of Colombia.

Pathogens

January 2025

Centro de Investigación Turipaná, Corporación Colombiana de Investigación Agropecuaria AGROSAVIA, km 13 vía Montería, Cereté 230550, Colombia.

Hemoparasitic diseases represent a significant problem with a considerable impact on tropical and subtropical areas of the world. These conditions cause economic losses associated with multi-organic failure and even the death of animals. In these areas, the hemoparasites are transmitted in an enzootic cycle when infectious cattle, such as persistently infected animals, including cows, contribute to the success of transmission.

View Article and Find Full Text PDF

An Improved Speed Sensing Method for Drive Control.

Sensors (Basel)

January 2025

Departamento de Ingeniería Electrónica, Universidad de Sevilla, 41092 Seville, Spain.

Variable-speed electrical drive control typically relies upon a two-loop scheme, one for torque/speed and another for stator current control. In modern drive control methods, the actual mechanical speed is needed for both loops. In practical applications, the speed is often acquired by incremental rotary encoders.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!