Background: Large tidal volumes during de novo acute hypoxemic respiratory failure (AHRF) may promote patient self-inflicted lung injury. Tidal volume assessment under high flow nasal cannula (HFNC) is not routinely feasible at the bedside. Our objective was to determine whether tidal volume during low-level continuous positive airway pressure (CPAP) could predict tidal volume during HFNC and to compare the physiological effects of HFNC and low-level CPAP.

Methods: Prospective, single-center study including 29 de novo AHRF patients treated with HFNC (50 to 60 L.min). Patients were monitored using electrical impedance tomography during HFNC then CPAP at 4 cmHO. Tidal volume during HFNC was calculated based on tidal impedance variation. The ability of tidal volume under low-level CPAP to predict tidal volume under HFNC was explored using Bland-Altman analysis. CPAP and HFNC were compared in terms of tidal volume, minute ventilation, respiratory comfort, dyspnea, oxygenation, ventilation distribution, end-expiratory lung volume, thoraco-abdominal asynchrony and recruitment.

Results: Under HFNC, patients had a tidal volume of 6.6 (5.9-8.7) mL.kg PBW. 20 (69%) patients exhibited a tidal volume between 4 and 8 mL.kg PBW, while in 5 (17%) patients it exceeded 9 mL.kg PBW. Tidal volume under CPAP was higher (9.4 (8.3-11) mL.kg PBW, p < 0.001). Tidal volumes under CPAP and under HFNC were modestly correlated (Spearman r = 0.50, p = 0.005). Bland-Altman analysis showed a bias of 2.4 mL.kg, with limits of agreement ranging from - 1.1 mL.kgto 5.9 mL.kg. Nevertheless, a larger (> 11.5 mL.kg PBW ) tidal volume under low-level CPAP predicted a larger (> 9 mL.kg PBW ) tidal volume under HFNC with 80% sensitivity and 96% specificity. Low-level CPAP was associated with increased minute ventilation, end-expiratory lung volume, and oxygenation as compared to HFNC. It decreased signs of respiratory distress in the most severe patients but was associated with lower comfort compared to HFNC.

Conclusion: Among ICU patients with de novo AHRF, tidal volume under HFNC was mostly protective. Tidal volume during CPAP at 4 cmHO did not predict tidal volume during HFNC. Such low-level CPAP was associated with increased tidal volume, minute ventilation, end-expiratory volume, and oxygenation.

Trial Registration: ClinicalTrials.gov ID NCT03919331. Registration date: 2019-03-26.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11584821PMC
http://dx.doi.org/10.1186/s13613-024-01408-wDOI Listing

Publication Analysis

Top Keywords

tidal volume
64
volume hfnc
24
mlkg pbw
24
volume
19
tidal
18
low-level cpap
16
hfnc
13
volume low-level
12
predict tidal
12
minute ventilation
12

Similar Publications

Aim: To describe the use of invasive mechanical ventilation core strategies, adjuvant treatments and the occurrence of barotrauma and prolonged ventilation in ICU patients with COVID-19 in Denmark, retrospectively.

Methods: All ICUs admitting COVID-19 patients in Denmark from 10 March 2020 to 2 April 2021 were invited to participate. All patients with COVID-19 who received invasive mechanical ventilation were included and data was retrospectively collected from electronic patient records.

View Article and Find Full Text PDF

Introduction: Ischemic stroke in patients with a systemic tumor disease or cancer not in remission (active tumors) is less well understood. Some aspects of such paraneoplastic strokes remind on a generalized cerebrovascular disorder. We hypothesized that cerebrovascular regulation in active tumor patients with a stroke is different from other patients with stroke who have no active tumor disease.

View Article and Find Full Text PDF

The diaphragm is the major muscle of inspiration accounting for approximately 70% of the inspired tidal volume. Point-of-care diaphragmatic ultrasound offers the ability to quantitatively assess diaphragmatic function, perform serial evaluations over time, and visualize structures above and below the diaphragm. Although interest in point-of-care ultrasound (POCUS) of the diaphragm is developing in the emergency medicine, assessment of the diaphragm and its function is not recognized as a core application by national organizations or expert guidelines.

View Article and Find Full Text PDF

Ventilation and features of the lung environment dynamically alter modeled intrapulmonary aerosol exposure from inhaled electronic cigarettes.

Sci Rep

December 2024

Division of Pulmonary and Critical Care, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, CA, 90095-1690, USA.

Electronic cigarettes (e-cigs) fundamentally differ from tobacco cigarettes in their generation of liquid-based aerosols. Investigating how e-cig aerosols behave when inhaled into the dynamic environment of the lung is important for understanding vaping-related exposure and toxicity. A ventilated artificial lung model was developed to replicate the ventilatory and environmental features of the human lung and study their impact on the characteristics of inhaled e-cig aerosols from simulated vaping scenarios.

View Article and Find Full Text PDF

Background: Epiglottic masses are often asymptomatic, making them difficult to detect during preoperative examinations. Consequently, anesthesiologists may face ventilation difficulties with no apparent cause. Epiglottic masses can sometimes obstruct laryngoscope insertion into the epiglottic vallecula, complicating general anesthesia induction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!