A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implementation of OSL nanoDot dosimetry in different treatment techniques for head and neck cancer. | LitMetric

Implementation of OSL nanoDot dosimetry in different treatment techniques for head and neck cancer.

Radiat Prot Dosimetry

Instituto Politécnico Nacional, Escuela Superior de Ingeniería Química e Industrias Extractivas, Edificio 6, Av. Luis Enrique Erro S/N, Unidad Profesional Adolfo López Mateos, 07738 Ciudad de México, México.

Published: November 2024

In recent decades, technological advances have been made in the field of radiotherapy and with it the emergence of new dosimetric systems for their calibration and commissioning, among other uses. Such is the case of the measurement in the build-up region, where there is no charged-particle equilibrium, which is reflected in the increase in surface dose for patient treatments and potential skin toxicities as a secondary effect. This study utilizes optically stimulated dosemeters (nanoDot) and the radiochromic film (EBT3) to measure skin doses in patients with head and neck cancer who received radiotherapy. Accurately depicting 15 patients with different diagnoses from 3 linear accelerators using 3D, intensity modulated radiation therapy, or volumetric arc therapy/RapidArc technology, these results were compared with those calculated in the treatment planning system (TPS) and obtaining a percentage of variation for the EBT3 ranged from 0.30% to 6.15%, while that observed for the nanoDot was from 0.51% to 4.88%. This difference may be attributed to the reproducibility of placement in patients. Therefore, for clinical use, nanoDot dosemeters are a viable alternative for in vivo dosimetry where rapid validation of planning system results is required.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncae217DOI Listing

Publication Analysis

Top Keywords

head neck
8
neck cancer
8
planning system
8
implementation osl
4
nanodot
4
osl nanodot
4
nanodot dosimetry
4
dosimetry treatment
4
treatment techniques
4
techniques head
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!