A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous detection of soot, temperature, and CH in laminar premixed flames using a multi-pass diode laser absorption spectrometer. | LitMetric

We report the development of a multi-pass diode laser absorption spectroscopy system for simultaneous measurements of soot volume fraction (SVF), temperature, and CH concentration using a single diode laser near 1.543 µm. A line-shaped beam spot pattern is chosen for the open-path Herriott multi-pass cavity, enabling sensitive detection at various heights above the burner with an effective optical absorption path length of approximately 1.2 m in a 6 cm diameter flame region. The gas parameters (temperature and CH concentration) and the SVF are determined from the absorption spectra of the target CH line pair and the laser extinction of the soot, which can be extracted from the detected signal, respectively. The performance of the system was confirmed in laminar premixed ethylene and air (CH/air) sooting flames produced by a standard bronze plug McKenna burner at four representative equivalence ratios. All the measurement results were compared with the two-dimensional (2D) computational fluid dynamics (CFD) simulations using a skeletal mechanism with the Moss-Brookes model. The good quantitative and qualitative agreement between the TDLAS measurements and 2D CFD simulations confirms the powerful capability of the developed system.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.539731DOI Listing

Publication Analysis

Top Keywords

diode laser
12
laminar premixed
8
multi-pass diode
8
laser absorption
8
temperature concentration
8
cfd simulations
8
simultaneous detection
4
detection soot
4
soot temperature
4
temperature laminar
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!