Due to the scattering and absorption of light, underwater images often exhibit degradation. Given the scarcity of paired real-world data and the inability of synthetic paired data to perfectly approximate real-world data, it's a challenge to restore these degraded images using deep neural networks. In this paper, a zero-shot underwater multi-scale image enhancement method (Zero-UMSIE) is proposed, which utilizes the isomorphism between the original underwater image and the re-degraded image. Specifically, Zero-UMSIE first estimates three latent components of the original underwater image: the global background light, the transmission map, and the scene radiance. Then, the estimated scene radiance is randomly mixed with the original underwater image to generate re-degraded images. Finally, a multi-scale loss and a set of tailored non-reference loss functions are employed to fine-tune the underwater image and enhance the generalization ability of the network. These functions implicitly control the learning preferences of the network and effectively address issues such as color bias and uneven illumination in underwater images, without the need for additional datasets. The proposed method is evaluated on three widely used real-world underwater image datasets. Extensive experiments on various benchmarks demonstrate that the proposed method is superior to state-of-the-art methods subjectively and objectively, which is competitive and applicable to diverse underwater conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.538120DOI Listing

Publication Analysis

Top Keywords

underwater image
20
original underwater
12
underwater
10
zero-shot underwater
8
underwater multi-scale
8
image
8
multi-scale image
8
image enhancement
8
enhancement method
8
underwater images
8

Similar Publications

Spectroscopic aspects of underwater digital holography of plankton.

Sci Rep

January 2025

Laboratory for Radiophysical and Optical Methods of Environmental Research, National Research Tomsk State University, Tomsk, Russia, 634050.

Monitoring the parameters and behavior of plankton makes it possible to assess the state of the aquatic ecosystem and detect the beginning of an environmental disaster at an early stage. In this respect, the most informative method for the in situ plankton study is underwater digital holography. This method allows obtaining information on the size, shape, and location of plankton individuals, as well as performing their classification and biotesting according to their behavioral responses using a submersible holographic camera non-invasively, in real time, and in the automatic mode.

View Article and Find Full Text PDF

Photoelectrochemical-Type Photodetectors Based on Ball Milling InSe for Underwater Optoelectronic Devices.

Nanomaterials (Basel)

December 2024

College of Chemistry, Chemical Engineering and Resource Utilization, Northeast Forestry University, Harbin 150040, China.

In this paper, InSe nanosheets were synthesized by a ball milling method, and photoelectrochemical-type photodetectors (PEC PDs) based on the ball milling InSe (M-InSe) were fabricated using simulated seawater as the electrolyte. M-InSe nanosheets show good absorption in the visible region of 450-600 nm. The M-InSe PEC PDs display a good self-powered photoresponse under 525 nm irradiation, including a high responsivity of 0.

View Article and Find Full Text PDF

Soft Metalens for Broadband Ultrasonic Focusing through Aberration Layers.

Nat Commun

January 2025

Key Laboratory of Underwater Acoustic Communication and Marine Information Technology of the Ministry of Education, College of Ocean and Earth Sciences, Xiamen University, Xiamen, China.

Aberration layers (AL) often present significant energy transmission barriers in microwave engineering, electromagnetic waves, and medical ultrasound. However, achieving broadband ultrasonic focusing through aberration layers like the human skull using conventional materials such as metals and elastomers has proven challenging. In this study, we introduce an inverse phase encoding method employing tunable soft metalens to penetrate heterogeneous aberration layers.

View Article and Find Full Text PDF

Comparison of the Efficacy of Endoscopic Continuous Perfusion Combined With Y-Shaped Incision and Microscopic Retroauricular Incision in the Treatment of Attic Cholesteatoma: A Randomized Prospective Study.

Ear Nose Throat J

January 2025

Department of Otolaryngology, Northern Jiangsu People's Hospital, Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, PR China.

This study aimed to compare the efficacy of continuous perfusion of underwater bone grinding combined with a -shaped incision versus a microscopic posterior ear incision in the treatment of attic cholesteatoma. Clinical trials were prospective studies from the Northern Jiangsu People's Hospital. Adult patients with middle ear cholesteatoma requiring ear surgery agreed to participate between September 2019 and September 2023 (age > 18).

View Article and Find Full Text PDF

Underwater image enhancement (UIE) is challenging since image degradation in aquatic environments is complicated and changing over time. Existing mainstream methods rely on either physical-model or data-driven, suffering from performance bottlenecks due to changes in imaging conditions or training instability. In this article, we attempt to adapt the diffusion model to the UIE task and propose a Content-Preserving Diffusion Model (CPDM) to address the above challenges.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!