To enhance the dynamic performance and stability of spacecraft attitude measurement, a commonly adopted approach is to integrate a star sensor with an inertial gyroscope. While an integrated sensor system offers benefits in high-precision and high-dynamic scenarios, it also introduces errors in the extrinsic parameters of the camera and gyroscope, directly contributing to increased fixed error in attitude determination. Hence, real-time correction of integrated system parameters becomes crucial for enhancing the accuracy of attitude estimation. However, a deep coupling relationship exists between the camera's principal point and the extrinsic parameters of the two sensors, unified calibration of system parameters increases the computational time to decouple all the parameters. In response to this challenge, a stepwise calibration method for system parameters is proposed. Firstly, the calibration of camera intrinsic parameters leverages the principle of invariant interior star angles, which are independent of extrinsic parameters. Secondly, based on the observation vector error model of the integrated sensor, observation equations and state equations are constructed, followed by proposing a 4-position maneuver strategy based on observability analysis to achieve rapid decoupling of gyroscope bias, attitude error, and extrinsic parameters. Simulation results affirm the effectiveness of the proposed method, extrinsic parameter errors reaching the arc-second level.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.533287DOI Listing

Publication Analysis

Top Keywords

extrinsic parameters
16
system parameters
12
parameters
10
star sensor
8
integrated sensor
8
extrinsic
5
on-orbit high-precision
4
calibration
4
high-precision calibration
4
calibration deep-coupled
4

Similar Publications

Biomimetic Active Stereo Camera System with Variable FOV.

Biomimetics (Basel)

December 2024

School of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China.

Inspired by the biological eye movements of fish such as pipefish and sandlances, this paper presents a novel dynamic calibration method specifically for active stereo vision systems to address the challenges of active cameras with varying fields of view (FOVs). By integrating static calibration based on camera rotation angles with dynamic updates of extrinsic parameters, the method leverages relative pose adjustments between the rotation axis and cameras to update extrinsic parameters continuously in real-time. It facilitates epipolar rectification as the FOV changes, and enables precise disparity computation and accurate depth information acquisition.

View Article and Find Full Text PDF

Polymer-Based Toothpastes and Their Ability in Control Tooth Extrinsic Stain.

J Esthet Restor Dent

December 2024

Department of Restorative Dentistry, University of São Paulo, School of Dentistry, São Paulo, São Paulo, Brazil.

Objectives: To synthesize experimental toothpastes (ETs) containing four different polymers (sodium linear polyphosphate [LPP]; chitosan [CHI]; sodium hexametaphosphate [HMP]; and sodium pyrophosphate [PP]) and test their ability in preventing and removing tooth extrinsic stain.

Methods: The tooth specimens were randomly assigned into six groups (n = 10): control (artificial saliva), regular toothpaste (RT-no whitening claim), ET 5% LPP, ET 0.5% CHI, ET 5% HMP, and ET 5% PP.

View Article and Find Full Text PDF

Aging of plastics and microplastics in the environment: a review on influencing factors, quantification methods, challenges, and future perspectives.

Environ Sci Pollut Res Int

December 2024

IFP Énergies Nouvelles (IFPEN), Direction Sciences de La Terre Et Technologies de L'Environnement, 1 Et 4 Avenue de Bois-Préau, 92852, Rueil-Malmaison Cedex, France.

The ubiquitous presence of fragmented plastic particles needs comprehensive understanding of its fate in the environment. The long-term persistence of microplastics (MPs) in the environment is a significant threat to the ecosystem. Even though various degradation mechanisms (physical, chemical, and biological) of commonly used plastics have been demonstrated, quantifying the degradation of MPs over time to predict the consequence of plastic littering and its persistence in the environment remains a challenge.

View Article and Find Full Text PDF

Background: One-third of patients with peritoneal carcinomatosis undergoing cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS-HIPEC) present alterations in conventional coagulation test results. However, perioperative coagulation has not been systematically investigated in these patients. This study aimed to investigate hemostatic changes in such patients.

View Article and Find Full Text PDF

Muscle composition is not a prognostic factor for muscle strength recovery after anterior cruciate ligament surgery by hamstring tendon autograft.

Orthop Traumatol Surg Res

December 2024

Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France; LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France.

Purpose: For the athlete, anterior Cruciate Ligament (ACL) rupture and its surgical management are often a turning point in their career. Success and time to return to sport are essential parameters for athletes and their support staff, so it is critical to understand the prognostic factors influencing return to sport after anterior cruciate ligament reconstruction (ACLR). The aim of this study was to determine the influence of hamstring muscle composition on muscle power following ACLR with autogenous hamstring grafts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!