A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Large-depth-range 3D measurement based on optimized multi-focal projection system. | LitMetric

High-speed and large-depth-range 3D measurement technology is of great importance in a variety of fields. Conventional binary defocusing methods can achieve high measurement speed, but their depth range is limited because the defocusing effect is insufficient near the focal plane in the ordinary projection system. To address this problem, we propose an optimized multi-focal projection system by introducing a cylindrical lens with optimal parameter configuration. Compared to traditional methods, the proposed method could overcome the constraint of defocusing region to obtain high-quality sinusoidal fringe patterns over large depth range without sacrificing the measurement speed. In this paper, the principle of multi-focal projection system and the related scheme of parameter configuration are presented in order to illustrate the role of the cylindrical lens and system parameters on modulating the distribution of defocusing kernel and removing the limitations of defocusing region. Experimental results show that the proposed multi-focal projection system with optimal parameter configuration increased the depth range from 150 mm to 725 mm over the conventional single-focal system, achieving greater depth range and better measurement results.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.529818DOI Listing

Publication Analysis

Top Keywords

projection system
20
multi-focal projection
16
depth range
16
parameter configuration
12
large-depth-range measurement
8
optimized multi-focal
8
measurement speed
8
cylindrical lens
8
optimal parameter
8
defocusing region
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!