A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a high-sensitivity and fast-response fiber temperature sensor utilizing TiCT MXene/PDMS composites and Vernier effect. | LitMetric

Precisely measuring temperature holds great significance for human daily life and industrial production. A high-sensitivity and fast-response optical fiber temperature sensor based on the vernier effect is proposed. A Fabry-Perot interferometer (FPI) filled with TiCT MXene and polydimethylsiloxane (PDMS) composites is employed as a sensing probe for the first time, and a cascaded Mach-Zender interferometer (MZI) as a reference unit due to its insensitivity to temperature. The temperature sensitivity of the FPI filled with TiCT MXene/PDMS composites is 1.63 nm/°C owing to the excellent thermal expansion characteristics of PDMS, and the response time is shortened from 3.021 s to 719 ms compared to that of the FPI filled with pure PDMS attributed to the high thermal conductivity of MXene. The cascading of FPI and MZI with similar free spectral ranges generates the vernier effect. The sensitivity is magnified by 19.44 times, reaching up to 31.62 nm/°C in the range of 36.5 - 37.2 °C, and the response time is 721 ms. Furthermore, experimental results demonstrate the sensor's good stability, implying its potential applications of the sensor in medical diagnosis, environmental monitoring and biosensing.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.530215DOI Listing

Publication Analysis

Top Keywords

fpi filled
12
high-sensitivity fast-response
8
fiber temperature
8
temperature sensor
8
tict mxene/pdms
8
mxene/pdms composites
8
filled tict
8
response time
8
temperature
5
development high-sensitivity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!