A surface plasmon resonance (SPR) sensor composed of photonic crystal fibers (PCFs) is designed for the detection of low-concentration liquids. The excellent sensing properties are attributed to the sensitivity enhancement at the dispersion turning point (DTP) of the surface plasmon polariton (SPP) modes. The sensor consists of two identical and structurally simple D-shaped PCFs together with a plasmonic thin film coated on the polished surface in direct contact with the analyte. Changes in the refractive index (RI) result in the splitting of the degenerate plasma peaks, thus allowing the monitoring of the analyte concentration variations by measuring the peak separation. In the RI range between 1.328 RIU and 1.33 RIU, the sensor exhibits an ultra-high sensitivity of 129,800 nm/RIU, which is 37.22 times higher than that of the unsensitized single D-shaped structure. Compared to fiber grating sensors operating in the vicinity of the cladding mode DTP, the spliced dual D-shaped PCF still has a predictably high mechanical strength. In addition, the RI detection range of the sensor can be changed by adjusting the slit width. The average sensitivities are 4.38 nm/g·L in the sodium chloride concentration range of 0 g/L to 100 g/L and 20.85 nm/g·L in the hemoglobin concentration range of 0 g/L to 20 g/L. Our results reveal that this SPR sensor based on PCFs has large potential in a variety of applications, especially biochemistry, due to its exceptional sensitivity, structural simplicity, and adjustable detection range.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.531112DOI Listing

Publication Analysis

Top Keywords

ultra-high sensitivity
8
photonic crystal
8
sensor based
8
dispersion turning
8
turning point
8
surface plasmon
8
spr sensor
8
detection range
8
concentration range
8
range g/l
8

Similar Publications

Background And Purpose: To evaluate various anatomical parameters and their relationship to chorda tympani nerve (CTN) injury and round window (RW) access during cochlear implantation.

Materials And Methods: Ultra-high-resolution CT images of 66 patients were retrospectively reviewed and compared with operative reports. The facial recess and the round window were analyzed, mainly using the chorda-facial angle (CFA), the width of the facial recess, the CTN-tympanic annulus distance, the RW-mastoid portion of the facial nerve angle, and the type of RW.

View Article and Find Full Text PDF

Background/objectives: Janus kinase inhibitors open new horizons for small-molecule drugs in treating inflammatory bowel disease, with ritlecitinib demonstrating significant efficacy in clinical trials for ulcerative colitis and Crohn's disease. Ritlecitinib, a second-generation JAK3 inhibitor, is a novel therapeutic agent for alopecia areata and other autoimmune conditions.

Methods: A new stability-indicating UHPLC-DAD-MS/MS method was developed, validated, and applied for a forced degradation study of ritlecitinib under ICH guidelines.

View Article and Find Full Text PDF

Very High-Energy Electron Therapy Toward Clinical Implementation.

Cancers (Basel)

January 2025

Intense Laser Irradiation Laboratory, National Institute of Optics, National Research Council of Italy, 56124 Pisa, Italy.

The use of very high energy electron (VHEE) beams, with energies between 50 and 400 MeV, has drawn considerable interest in radiotherapy due to their deep tissue penetration, sharp beam edges, and low sensitivity to tissue density. VHEE beams can be precisely steered with magnetic components, positioning VHEE therapy as a cost-effective option between photon and proton therapies. However, the clinical implementation of VHEE therapy (VHEET) requires advances in several areas: developing compact, stable, and efficient accelerators; creating sophisticated treatment planning software; and establishing clinically validated protocols.

View Article and Find Full Text PDF

Transient protection has the advantage of ultra-high-speed action, but traditional transient protection is susceptible to the influence of two fault condition attributes, namely, transition resistance and initial angle of fault, and there are the problems of insufficient sensitivity and insufficient reliability under weak faults. To this end, the propagation characteristics of high-frequency components of transient voltage in bus and line systems are explored, and a new method of unit protection based on the entropy difference in transient voltage information is proposed. In order to solve the problem of single-ended transient protection not being able to reliably distinguish line faults from bus faults and adjacent line first-end faults, the difference between the entropy of line voltage and the entropy of bus voltage was introduced as a fault characteristic.

View Article and Find Full Text PDF

Development and Validation of a High-Throughput Quantification Method of Crown Procyanidins in Different Wines by UHPLC-Q-TOF.

Methods Protoc

January 2025

Univ. Bordeaux, INRAE, Bordeaux INP, Bordeaux Sciences Agro, UMR 1366, OENO, ISVV, F-33882 Villenave d'Ornon, France.

Procyanidins are widely distributed in plant-derived foods, and consist of flavanol oligomers and polymers. Recently, the crown procyanidin sub-family, characterised by a unique macrocyclic structure, has been identified in grapes and wine. This study reports the development and validation of a rapid and quantitative analytical method measuring crown procyanidin concentration in red and white wines using ultra-high-performance liquid chromatography (UHPLC) coupled with a Q-TOF mass spectrometer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!