A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Arterial blood pressure monitoring in stroke cohorts: the impact of reduced sampling rates to optimise remote patient monitoring. | LitMetric

Objective: Remote patient monitoring (RPM) beat-to-beat blood pressure (BP) provides an opportunity to measure poststroke BP variability (BPV), which is associated with clinical stroke outcomes. BP sampling interval (SI) influences ambulatory BPV, but RPM BP SI optimisation research is limited. SI and RPM device capabilities require compromises, meaning SI impact requires investigation. Therefore, this study assessed healthy and stroke subtype BPV via optimised BP sampling, aiding sudden BP change identification and potentially assisting cardiovascular event (recurrent stroke) prediction.

Methods: Leicester Cerebral Haemodynamic Database ischaemic [acute ischaemic stroke (AIS), n  = 68] and haemorrhagic stroke (intracerebral haemorrhage, n  = 12) patient and healthy control (HC, n  = 40) baseline BP data were analysed. Intrasubject and interpatient SD (SD i /SD p ) represented individual/population variability with synthetically altered SIs. Matched-filter approaches using cross-correlation function detected sudden BP changes.

Results: At SIs between 1 and 180 s, SBP and DBP SD i staticised while SD p increased at SI < 30 s. Mean BP and HR SD i and SD p increased at SI < 60s. AIS BPV, normalised to SI1s, increased at SI30s (26%-131%) and SI120s (1%-274%). BPV increased concomitantly with SI. Cross-correlation analysis showed HC and AIS BP sudden change detection accuracy reductions with increasing SI. Positive BP deviation detection fell 48.48% (SI10s) to 78.79% (SI75s) in HC and 67.5% (SI10s) to 100% (SI75s) in AIS. Negative BP deviation detection fell 50% (SI10s) to 82.35% (SI75s) in HC and 52.27% (SI10s) to 95.45% (SI75s) in AIS.

Conclusion: Sudden BP change detection and BPV are relatively robust to SI increases within certain limits, but accuracy reductions generate unacceptable estimates, considerable within RPM device design. This research warrants further SI optimisation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBP.0000000000000721DOI Listing

Publication Analysis

Top Keywords

blood pressure
8
remote patient
8
patient monitoring
8
stroke
6
arterial blood
4
pressure monitoring
4
monitoring stroke
4
stroke cohorts
4
cohorts impact
4
impact reduced
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!