Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
When implantable medical devices come into contact with blood, acute thrombosis and inflammation often occur due to the adhesion and denaturation of plasma proteins, ultimately degrading device performance. To address this issue, we developed a gel-like coating with superhydrophilic properties, incorporating a heparin based outer layer designed to minimize foreign body reactions and enhance hemocompatibility. The coating was engineered using a layer-by-layer (LbL) assembly of poly-l-lysine (PLL), laponite (Lap), and heparin (Hep), utilizing electrostatic interactions. The successful formation of stable layers was confirmed by QCM-D analysis. The inner layer, composed of PLL/Lap multilayers, formed a gel-like structure that maintained superhydrophilicity and effectively prevented cell adhesion. The outermost PLL/Hep multilayers significantly suppressed thrombus formation by inhibiting plasma protein and red blood cell adsorption as well as platelet activation. The coating exhibited excellent stability, retaining its superhydrophilic properties and heparin functionality even after 7 days of immersion in DPBS. Additionally, in vitro hemocompatibility and cytocompatibility tests confirmed its non-toxicity and overall biocompatibility. These results highlight the potential application of this coating to various implantable medical devices, providing a robust solution for improving device performance and safety.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.carbpol.2024.122875 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!