Adsorption equilibria of CO, CH, and their mixtures were measured on binderless pellets of NIST reference zeolite NaY (RM 8850) using a static gravimetric setup. The unary adsorption isotherms are reported at temperatures from 298 to 393 K up to a pressure of 3 MPa and compare favorably with independent results on RM 8850 powder. The competitive adsorption measurements were performed at temperatures from 298 to 353 K and up to 3 MPa for three premixed gas mixtures with CO molar feed compositions of 0.25, 0.50, and 0.75. The results constitute the first competitive adsorption dataset reported for any of the NIST reference materials. RM 8850 shows a strong selectivity for CO adsorption toward CH. The experimental unary and binary adsorption isotherms are accurately modeled using the simplified statistical isotherm model (SSI). Notably, the agreement with the model improves only slightly (and within experimental uncertainties) when the whole dataset is used for parameter fitting as opposed to only using the unary data.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11571112 | PMC |
http://dx.doi.org/10.1021/acs.jced.4c00358 | DOI Listing |
Foods
January 2025
Faculty of Technology and Metallurgy, University of Belgrade, 11120 Belgrade, Serbia.
A rapid and efficient ultrasound-assisted extraction (UAE) procedure followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of 14 rare earth elements (REEs) (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu), along with yttrium (Y) and scandium (Sc), in coffee samples. The method was validated using certified reference material (NIST SRM 1547), recovery tests at four fortification levels, and comparisons with microwave-assisted digestion (MAD). Excellent accuracy and precision were achieved, with recovery rates ranging from 80.
View Article and Find Full Text PDFAnal Bioanal Chem
January 2025
Statistical Engineering Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, 20899-8980, USA.
Closely related species of Salmonidae, including Pacific and Atlantic salmon, can be distinguished from one another based on nucleotide sequences from the cytochrome c oxidase sub-unit 1 mitochondrial gene (COI), using ensembles of fragments aligned to genetic barcodes that serve as digital proxies for the relevant species. This is accomplished by exploiting both the nucleotide sequences and their quality scores recorded in a FASTQ file obtained via Next Generation (NextGen) Sequencing of mitochondrial DNA extracted from Coho salmon caught with hook and line in the Gulf of Alaska. The alignment is done using MUSCLE (Muscle 5.
View Article and Find Full Text PDFInt J Thermophys
January 2024
Applied Chemicals and Materials Division, National Institute of Standards and Technology, Boulder, CO 80305, USA.
Sound speed data measured using a dual-path pulse-echo instrument are reported for pure -1,2-dichloroethene (R-1130(E)) and an azeotropic blend of -1,1,1,4,4,4-hexafluorobutene (R-1336mzz(Z)) and R-1130(E) with a composition of 74.8 mass % R-1336mzz(Z) with the balance being R-1130(E). The azeotropic blend of R-1336mzz(Z)/1130(E) is classified as R-514A in ANSI/ASHRAE standard 34.
View Article and Find Full Text PDFMicrobiol Spectr
January 2025
Complex Microbial Systems Group, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland, USA.
The experimental methods employed during metagenomic sequencing analyses of microbiome samples significantly impact the resulting data and typically vary substantially between laboratories. In this study, a full factorial experimental design was used to compare the effects of a select set of methodological choices (sample, operator, lot, extraction kit, variable region, and reference database) on the analysis of biologically diverse stool samples. For each parameter investigated, a main effect was calculated that allowed direct comparison both between methodological choices (bias effects) and between samples (real biological differences).
View Article and Find Full Text PDFChemMedChem
January 2025
National Institute of Standards and Technology, Material Measurement Laboratory, UNITED STATES OF AMERICA.
Antibody-based pharmaceuticals are the leading biologic drug platform (> $75B/year). Despite a wealth of information collected on them, there is still a lack of knowledge on their inter-domain structural distributions, which impedes innovation and development. To address this measurement gap, we have developed a new methodology to derive biomolecular structure ensembles from distance distribution measurements via a library of tagged proteins bound to an unlabeled and otherwise unmodified target biologic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!