A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Possibilities and Limitations in Substituting anti-Drug Antibody Titers with Signal-to-Noise Ratios: A Comprehensive Comparison Using Two Clinical Trial Datasets of Adalimumab. | LitMetric

Possibilities and Limitations in Substituting anti-Drug Antibody Titers with Signal-to-Noise Ratios: A Comprehensive Comparison Using Two Clinical Trial Datasets of Adalimumab.

AAPS J

Clinical Bioanalysis Group, Samsung Bioepis Co., Ltd, 76, Songdogyoyuk-ro, Yeonsu-gu, Incheon, 21987, Republic of Korea.

Published: November 2024

Immunogenicity assessment is vital in clinical trials and is measured through a multi-tiered approach (screening, confirmatory and titer assays). However, recent studies have suggested that titer results could be reported from ADA signal-to-noise ratios (S/N ratios=sample mean signal/negative control mean signal). More data analysis using two clinical trials of adalimumab: SB5-1003 (single-dose, healthy participants) and SB5-4001 (multiple-dose, interchangeability study, patients with plaque psoriasis), therefore, is indispensable whether substituting ADA S/N ratio as an alternative way of reporting titer results has no impact on interpretation on clinical outcome. In this study, we demonstrated that there is a strong correlation between S/N ratios and titers and no impact on overall PK results. Nonetheless, sub-analyses with time or adalimumab level showed a change in the regression between S/N ratios and titers, leading to different titer values from the same S/N ratio. These data demonstrate that S/N ratios may fully replace titers in limited circumstances such as a biosimilar study which goal is to prove equivalence between the originator and candidate product, but need a caution in other cases.

Download full-text PDF

Source
http://dx.doi.org/10.1208/s12248-024-00991-xDOI Listing

Publication Analysis

Top Keywords

s/n ratios
12
signal-to-noise ratios
8
clinical trials
8
s/n ratio
8
ratios titers
8
s/n
6
ratios
5
possibilities limitations
4
limitations substituting
4
substituting anti-drug
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!