To date, the use of the most suitable first-pass technique for Mechanical Thrombectomy is still debated. In last years, several observational studies have suggested noninferiority or superiority of A Direct Aspiration first-Pass Technique (ADAPT) technique to achieve better reperfusion in comparison to stent retriever. While ASA/AHA 2018 guidelines recommend that patients with AIS should receive Mechanical Thrombectomy with a stent retriever, last European Stroke Organization guidelines report no evidence that stent retriever compared with contact aspiration could improve reperfusion rate. ADAPT is based on aspiration alone as the primary mechanism of thrombectomy and, if initially unsuccessful, then incorporating adjunctive alternatives. ADAPT improvement is also related to last generation of aspiration catheters. The purpose of this review is to report ADAPT principles, technique, efficacy, and safety as first-line treatment for acute ischemic stroke with the latest generation of reperfusion devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11577322PMC
http://dx.doi.org/10.1177/19714009241303063DOI Listing

Publication Analysis

Top Keywords

first-pass technique
12
stent retriever
12
direct aspiration
8
aspiration first-pass
8
technique adapt
8
acute ischemic
8
ischemic stroke
8
mechanical thrombectomy
8
technique
6
adapt
5

Similar Publications

To assess the utility of IVIM parameters in evaluating uterine fibroid blood flow compared to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) derived blood flow. Sixteen premenopausal women with uterine fibroids were enrolled in this prospective study. Pelvic MRI scans were obtained for each subject, both with and without continuous intravenous infusion of oxytocin, known to decrease significantly uterine fibroid blood flow, to assess the changes in blood flow of uterine fibroids.

View Article and Find Full Text PDF

Gadopiclenol Enables Reduced Gadolinium Dose While Maintaining Quality of Pulmonary Arterial Enhancement for Pulmonary MRA: An Opportunity for Improved Safety and Sustainability.

Invest Radiol

January 2025

From the Departments of Radiology (J.F.H., S.Y.C., J.-P.G., J.S., P.N., S.B.R., T.M.G.), Biomedical Engineering (S.B.R., T.M.G.), Medical Physics (S.Y.C., S.B.R., T.M.G.), Medicine (S.B.R.), and Emergency Medicine (S.B.R.), University of Wisconsin-Madison, WI; and Department of Diagnostic and Interventional Radiology (J.F.H., J.-P.G.), University Hospital Würzburg, Würzburg, Germany.

Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.

View Article and Find Full Text PDF

Objective: The purpose of this study was to explore microvascular function impairment using first-pass cardiovascular magnetic resonance (CMR) in patients with Takotsubo syndrome (TS). Moreover, we explored myocardial microcirculation in patients with TS and related this to demographic data, cardiovascular risk factors, clinical parameters, cardiac biomarkers, and cardiac function.

Methods: This retrospective study performed CMR first-pass perfusion scans in 42 consecutive patients with TS (37 females, 70.

View Article and Find Full Text PDF

Introduction: We aimed to explore if anatomical and technical features could interact and favor the chances of reperfusion according to the treatment strategy: combined technique (CoT) of mechanical thrombectomy (MT) with contact aspiration and stent-retriever (SR) versus SR alone.

Methods: Retrospective analysis of a prospective MT database for carotid terminus or MCA-M1 occlusion, first-line SR alone or CoT, and angiographic run with SR deployed on the first pass. The primary analysis involved the interaction between clinical and angiographic characteristics and first-line MT modality on first-pass effect (FPE; first pass eTICI2c-3).

View Article and Find Full Text PDF

A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-months success rates.

Heart Rhythm

January 2025

Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Background: Focal pulsed-field ablation (F-PFA) integrated in electroanatomical mapping (EAM) systems allows tailored lesion sets in patients with atrial fibrillation (AF).

Objective: To determine feasibility, safety and 6-months outcome of F-PFA for a tailored substrate-based catheter ablation (CA) approach in patients with AF and advanced atrial substrate.

Methods: Consecutive patients with AF and advanced atrial substrate treated by a F-PFA system (Cardiofocus) through contact-force sensing catheters integrated in EAM systems were prospectively enrolled.