Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Simple and stable generation of monodispersed droplets with volume from picolitre to nanoliter is one of the key factors in high-throughput quantitative microreactors for chemical and biomedical applications. In this work, an efficient method that could realize simple manipulating microflow with a broad operation window for preparing monodispersed droplets with controllable diameter is developed. The microfluidic device is constructed by inserting a capillary with an oblique angle (α) into the continuous phase, named a floating capillary-based open microfluidic device (FCOMD). The transition of droplet-generating mode between dripping and jetting can be achieved by changing capillary number and α. A computational model based on the volume-of-fluid/continuum-surface-force method to explain the controllability of α on the droplet formation regime and droplet breakage, verifying the synergistic effect of ΔP and Fb, facilitates the droplet pinching. A descending order of Pn of capillary with different α is that 45° > 30° > 15° > 60° > 75°, leading to the same order of generated droplet's D. When compared with the traditional capillary co-flow device, the generating throughput of the integrated FCOMD obtained by integrating different numbers of capillaries is at least ten times. Moreover, water in oil, oil in water double-emulsion, colloidal dispersed droplets, and liquid crystal droplets with diameters ranging from 25 to 800 μm are prepared on-demand by the FCOMD, indicating the universality of the microfluidic device. Thus, the FCOMD shows the features of simplicity, practicability, and flexibility, offering valuable guidance for generating controllable droplets with wide size change and showing a great potential application in material science, foods, pharmaceuticals, and cosmetics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0234937 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!