Background: Video assisted cardiopulmonary resuscitation (V-CPR) has demonstrated to be efficient in improving CPR quality and patient outcomes, as Emergency Medical Service (EMS) dispatchers can use the video stream of a caller for diagnostic purposes and give instructions in a CPR scenario. However, the new challenges faced by EMS dispatchers during video-guided CPR (V-CPR)-such as analyzing the video stream, providing feedback to the caller, and managing stress-demand innovative solutions. This study explores the feasibility of incorporating an open-source "machine-learning" tool (artificial intelligence - AI), to evaluate the feasibility and accuracy in correctly detecting the actual compression frequency and compression depth in video footage of a simulated CPR.

Design: MediaPipe Pose Landmark Detection (Google LLC, Mountain View, CA, USA), an open-source AI software using "machine-learning" models to detect human bodies in images and videos, was programmed to assess compression frequency an depth in nine videos, showing CPR on a resuscitation manikin. Compression frequency and depth were assessed from compression to compression with AI software and were compared to the manikin's internal software (QCPR, Laerdal, Stavanger, Norway). After testing for Gaussian distribution, means of non-gaussian data were compared using Wilcoxon matched-pairs signed rank test and the Bland Altman method.

Main Results: MediaPipe Pose Landmark Detection successfully identified and tracked the person performing CPR in all nine video sequences. There were high levels of agreement between compression frequencies derived from AI and manikin's software. However, the precision of compression depth showed major inaccuracies and was overall not accurate.

Conclusions: This feasibility study demonstrates the potential of open-source "machine-learning" tools in providing real-time feedback on V-CPR video sequences. In this pilot study, an open-source landmark detection AI software was able to assess CPR compression frequency with high agreement to actual frequency derived from the CPR manikin. For compression depth, its performance was not accurate, suggesting the need for adjustment. Since the software used is currently not intended for medical use, further development is necessary before the technology can be evaluated in real CPR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11570746PMC
http://dx.doi.org/10.1016/j.resplu.2024.100825DOI Listing

Publication Analysis

Top Keywords

compression frequency
20
compression depth
16
compression
12
landmark detection
12
cpr
9
frequency compression
8
artificial intelligence
8
ems dispatchers
8
video stream
8
open-source "machine-learning"
8

Similar Publications

Sparse loudspeaker array design for wideband frequency-invariant beamforming with multiple targets.

J Acoust Soc Am

January 2025

Key Laboratory of Modern Acoustics, Institute of Acoustics, Nanjing University, Nanjing 210093, China.

Beamforming technology using loudspeaker arrays is widely used in sound applications, but current sparse array design methods focus on optimizing a single beam for a single target direction, limiting their applicability to multi-channel sound systems. This paper presents a design method for sparse loudspeaker line arrays to generate wideband frequency-invariant beams in multiple target directions. A model based on tapped delay lines is developed and a two-stage design approach is proposed.

View Article and Find Full Text PDF

The amount of information contained in speech signals is a fundamental concern of speech-based technologies and is particularly relevant in speech perception. Measuring the mutual information of actual speech signals is non-trivial, and quantitative measurements have not been extensively conducted to date. Recent advancements in machine learning have made it possible to directly measure mutual information using data.

View Article and Find Full Text PDF

Empty sella (ES) is a radiographic finding defined by the presence of cerebrospinal fluid in the sella turcica, with associated compression of the pituitary gland. Empty sella syndrome (ESS) is the combination of this radiographic finding with endocrine, ophthalmological, and/or neurological symptoms. The focus of this literature review is to synthesize information about asymptomatic or incidental ES specifically, meaning the radiologic finding of an empty sella without symptoms.

View Article and Find Full Text PDF

Introduction: Non-nutritive sucking (NNS) is commonly employed to assist in the development of preterm infants facing feeding challenges. The effectiveness of NNS interventions on sucking performance (suction and expression/compression component of sucking) in this population has not yet to be systematically explored.

Aims: To review the literature on the effects of NNS on sucking performance in preterm infants.

View Article and Find Full Text PDF

Retrospective Study of Morton's Neuroma: Clinical, Paraclinical, and Therapeutic Assessment of 10 Cases.

Cureus

December 2024

Physical Medicine and Rehabilitation, Faculty of Medicine of Oujda, Mohammed VI University Hospital of Oujda, Mohammed First University of Oujda, Oujda, MAR.

Background Morton's neuroma is a common cause of forefoot pain, typically occurring in the third metatarsal space and characterized by symptomatic nerve compression. This condition often leads to significant functional impairment, affecting weight-bearing activities and limiting appropriate footwear due to pain and discomfort. Objective This study aims to evaluate the outcomes of conservative interventional treatment for Morton's neuroma, specifically focusing on corticosteroid injections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!