A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Rh- Positive Blood Group on Distortion Product Otoacoustic Emission Input-Output Function. | LitMetric

AI Article Synopsis

  • * It involved 60 young female college students, divided into four groups based on blood type (A, B, AB, O), who underwent Distortion Product Otoacoustic Emission (DPOAE) testing at various frequencies.
  • * The findings indicated no significant differences in the DPOAE input-output function across the different blood groups, suggesting blood type does not impact auditory function in this context.

Article Abstract

The blood group system of human beings can impact the health and auditory system. There are correlations between various audiological test findings and blood groups. Studies have shown that persons with the O blood group have reduced resonance frequency of the middle ear and amplitude of otoacoustic emissions. Therefore, Otoacoustic emissions (OAE) results could be different across blood groups. The current study aimed to determine the difference in Distortion product otoacoustic emission input-output function in persons with varying groups of blood. A total of sixty college-going young female adults, aged between 18 and 25 years, participated in the current study. They were divided into four groups, each with 15 participants based on the blood group type (A, B. AB. O). The subjects underwent Distortion product otoacoustic emission (DPOAE) input-output function on the following frequencies: 703 Hz,1060 Hz,1416 Hz,2114 Hz,2827 Hz,4243 Hz, and 5645 Hz. The analysis showed no significant difference in the area and slope of the Distortion product otoacoustic emission input-output function at all frequencies. Thus, the study's result shows no effect of the blood group on Distortion product otoacoustic emission input- output function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569030PMC
http://dx.doi.org/10.1007/s12070-024-05036-5DOI Listing

Publication Analysis

Top Keywords

blood group
20
distortion product
20
product otoacoustic
20
otoacoustic emission
20
input-output function
16
emission input-output
12
blood
8
group distortion
8
blood groups
8
otoacoustic emissions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!