Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Spherical biosamples such as immunobeads, cells, and cell aggregates have been widely used in bioapplications. The bioactivity of individual spherical biosamples in highly sensitive assays and individual analyses must be evaluated in a high-throughput manner. Electrochemiluminescence (ECL) imaging was recently proposed for the high-throughput analysis of diffusive molecules from spherical biosamples. ECL imaging involves the placing of spherical biosamples on a flat electrode filled with a solution. The biosamples produce (or consume) biological/chemical molecules such as HO and O, which diffuse to form a concentration gradient at the electrode. The ECL signals from the molecules are then measured to obtain the concentration profile, which allows the flux to be estimated, from which their bioactivities can be successfully calculated. However, no studies on theoretical approaches for spherical biosamples on flat surfaces have been conducted using ECL imaging. Therefore, this paper presents a novel spherical diffusion theory for spherical biosamples on a flat surface, which is based on the common spherical diffusion theory and was designated as the extended spherical diffusion theory. First, the concepts behind this theory are discussed. The theory is then validated by comparison with a simulated analysis. The resulting equation successfully expresses the concentration profile for the entire area. The glucose oxidase activity in the hydrogel beads is subsequently visualized using ECL imaging, and the enzymatic product flux is calculated using the proof-of-concept theory. Finally, a time-dependent simulation is conducted to fill the gap between the theoretical and experimental data. This paper presents novel guidelines for this analysis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11618750 | PMC |
http://dx.doi.org/10.1021/acs.analchem.4c03167 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!