Protocol for the playback of phantom echoes from approaching objects to scanning bats.

STAR Protoc

Faculty of Life and Medical Sciences, Doshisha University, Kyotanabe 610-0394, Japan. Electronic address:

Published: December 2024

Because bats emit ultrasound and listen to echoes to perceive their surroundings, presenting phantom echoes is useful for understanding their perception of echolocation. Here, we present a protocol for the real-time playback of phantom echoes, especially from approaching objects. We describe steps for presenting virtual objects using a microphone, digital signal processor, and loudspeaker to induce the escape behavior of bats. We then detail procedures for clarifying their detection algorithm for approaching objects. For complete details on the use and execution of this protocol, please refer to Yoshida et al..

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11615588PMC
http://dx.doi.org/10.1016/j.xpro.2024.103453DOI Listing

Publication Analysis

Top Keywords

phantom echoes
12
approaching objects
12
playback phantom
8
echoes approaching
8
protocol playback
4
echoes
4
objects
4
objects scanning
4
scanning bats
4
bats bats
4

Similar Publications

Double-quantum filtered Na NMR and MRI: Selective detection of ordered sodium in an inhomogeneous B field.

J Magn Reson

November 2024

Sir Peter Mansfield Imaging Centre, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.

Double-quantum filtered Na NMR experiments with one or two "magic angle" (54.7°) pulses in the filter step are widely used for selective observation of sodium ions that are interacting with ordered biological structures ("ordered sodium") and hence exhibit a distribution of quadrupolar splittings in their NMR spectrum. This approach has recently been extended to Na MRI where the conventional experiment has been modified, omitting the 180° pulse to reduce the absorption of radiofrequency energy during human studies.

View Article and Find Full Text PDF

Variable-flip-angle 3D spiral-in-out turbo spin-echo imaging using concomitant gradient compensation and echo reordering at 0.55 T.

Magn Reson Med

November 2024

Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.

Article Synopsis
  • Developed a single-slab 3D spiral turbo spin echo (spiral SPACE) imaging technique for 1-mm isotropic whole-brain T-weighted imaging using a 0.55T scanner focused on high scan efficiency.
  • Implemented methods included gradient infidelity correction, phase error compensation during readouts, and adjusted RF pulses to achieve enhanced echo trains, leading to improved image quality.
  • Results indicated a 15%-25% improvement in signal-to-noise ratio (SNR) for spiral SPACE over Cartesian SPACE, showing reduced artifacts and blurring in tested subjects.
View Article and Find Full Text PDF

Protocol for the playback of phantom echoes from approaching objects to scanning bats.

STAR Protoc

December 2024

Faculty of Life and Medical Sciences, Doshisha University, Kyotanabe 610-0394, Japan. Electronic address:

Because bats emit ultrasound and listen to echoes to perceive their surroundings, presenting phantom echoes is useful for understanding their perception of echolocation. Here, we present a protocol for the real-time playback of phantom echoes, especially from approaching objects. We describe steps for presenting virtual objects using a microphone, digital signal processor, and loudspeaker to induce the escape behavior of bats.

View Article and Find Full Text PDF

Conventional diffusion-weighted imaging (DWI) sequences employing a spin echo or stimulated echo sensitize diffusion with a specific b-value at a fixed diffusion direction and diffusion time (Δ). To compute apparent diffusion coefficient (ADC) and other diffusion parameters, the sequence needs to be repeated multiple times by varying the b-value and/or gradient direction. In this study, we developed a single-shot multi-b-value (SSMb) diffusion MRI technique, which combines a spin echo and a train of stimulated echoes produced with variable flip angles.

View Article and Find Full Text PDF

Purpose: Fresh blood imaging (FBI) utilizes physiological blood signal differences between diastole and systole, causing a long acquisition time. The purpose of this study is to develop a fast FBI technique using a centric k - k k-space trajectory (cFBI) and an exponential refocusing flip angle (eFA) scheme with fast longitudinal restoration.

Methods: This study was performed on 8 healthy subjects and 2 patients (peripheral artery disease and vascular disease) with informed consent, using a clinical 3-Tesla MRI scanner.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!