An experimental testbed was constructed to rigorously assess the fundamental limits of light-wave sensing-an economic, non-contact vitals monitoring approach previously reported. We improve the testbed using lock-in amplification and demonstrate that a photodetector and a commonplace array of infrared LEDs are sufficient to detect respiratory motion and quantify respiration rate up to 2.5 meters away. We propose a novel scattering model, from which we derive the performance limits of the light-wave sensing system in terms of a theoretical range resolution limited by the dynamic range of the system. Using a robotic breathing phantom, we experimentally assess, for the first time, the range resolution of the testbed system and compare this to theoretical predictions. This work also introduces a process for generating stochastic respiration patterns, which may prove broadly useful to the designers of breathing phantoms. Holistically exploring practical challenges and analytical models, this paper serves as a unique and comprehensive tutorial for understanding and designing light-wave sensing systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563342 | PMC |
http://dx.doi.org/10.1364/BOE.514776 | DOI Listing |
Biomed Opt Express
November 2024
School of Electrical and Computer Engineering, 200 Engineering South, Oklahoma State University, Stillwater, OK 74078, USA.
An experimental testbed was constructed to rigorously assess the fundamental limits of light-wave sensing-an economic, non-contact vitals monitoring approach previously reported. We improve the testbed using lock-in amplification and demonstrate that a photodetector and a commonplace array of infrared LEDs are sufficient to detect respiratory motion and quantify respiration rate up to 2.5 meters away.
View Article and Find Full Text PDFJ Phys Condens Matter
October 2024
Prokhorov General Physics Institute of the Russian Academy of Sciences, 119991 Moscow, Russia.
A quantum theory of spin dynamics in the rare-earth orthoferrites excited by terahertz laser pulses is developed. The study demonstrates that dynamic magnetic configurations, triggered by a light pulse, exhibit stability even after the excitation source is ceased. The magnitude of post-excitation oscillations is linked to the ratio between the frequency of rare-earth ion excitations and the frequency of the external source.
View Article and Find Full Text PDFAnal Sci
July 2024
Xi'an Northwest Geological Research Institute for Nonferrous Metals Co., Ltd., 25 Xiying Road, Xi'an, 710054, China.
Based on the automatic light wave ashing instrument, palladium nitrate was used as an ashing aid for the first time to collect selenium in the process of food ashing pre-treatment, and a method for the determination of selenium in food by ashing method was established with inductively coupled plasma mass spectrometry. At the same time, the effects of magnesium nitrate, rhodium nitrate, and nickel nitrate as ashing aids on selenium collection were investigated using certified plant standard materials. The capture of selenium by magnesium nitrate, rhodium nitrate, and nickel nitrate as ashing aids did not exceed 50%.
View Article and Find Full Text PDFHybrid systems based on Brillouin optical time domain analysis (BOTDA) utilizing Rayleigh backscattering light wave as a probe have enabled single-end and long-range distributed sensing for multiple parameters. However, the spatial resolution for dynamic parameter measurement is limited, and the frequency scanning process of BOTDA is time-consuming. To address these challenges, we propose a hybrid system that combines BOTDA and time-gated digital optical frequency domain reflectometry (TGD-OFDR), aiming to enhance the spatial resolution of dynamic measurements without compromising the system's signal-to-noise ratio and eliminate the frequency scanning process of BOTDA.
View Article and Find Full Text PDFThe field of digital holography has been significant developed in recent decades, however, the commercialization of digital holograms is still hindered by the issue of large data sizes. Due to the complex signal characteristics of digital holograms, which are of interferometric nature, traditional codecs are not able to provide satisfactory coding efficiency. Furthermore, in a typical coding scenario, the hologram is encoded and then decoded, leading to a numerical reconstruction via a light wave propagation model.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!