Pseudotumors are a rare complication of total hip arthroplasty (THA), arising from local soft tissue reactions. These reactions can lead to painful joint effusions and prosthetic loosening, often necessitating revision surgery. Metal-on-metal and metal-on-polyethylene prostheses are particularly prone to this complication due to the accumulation of metal debris from prosthetic wear, which represents a significant drawback. In contrast, ceramic-on-ceramic (CoC) prostheses are considered a superior alternative, offering lower wear rates and avoiding complications related to metal debris. This case report presents a rare instance of pseudotumor formation in a CoC THA. A 57-year-old patient underwent a cementless CoC THA in 2010. Despite developing a pulmonary embolism, the patient experienced no prosthetic-related complications until 2021, when they presented to the Royal Orthopaedic Hospital with concerns about a deep vein thrombosis. MRI and ultrasound scans of the hip revealed a complex collection involving the iliopsoas bursa and a small joint effusion, prompting a biopsy. Histopathology confirmed a pseudotumor with tissue necrosis, macrophages, neutrophils, and ceramic debris. In 2024, the patient underwent revision arthroplasty with excision of the pseudotumor. The original prosthesis was well-fixed, with minimal damage to the ceramic head and acetabular liner, and there were no signs of infection or metallosis. Following the revision, the patient's pain resolved, and they were satisfied with the outcome of the surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563772PMC
http://dx.doi.org/10.7759/cureus.71518DOI Listing

Publication Analysis

Top Keywords

total hip
8
hip arthroplasty
8
case report
8
metal debris
8
coc tha
8
patient underwent
8
pseudotumor
4
pseudotumor ceramic-on-ceramic
4
ceramic-on-ceramic total
4
arthroplasty case
4

Similar Publications

Background: Total hip arthroplasty (THA) is generally considered a successful operation for patients with advanced hip arthritis. Hip abductor pathology can lead to diminished outcomes. The prevalence of hip abductor pathology in patients undergoing THA is not well described.

View Article and Find Full Text PDF

Background: Robotic-assisted total joint arthroplasty (TJA) has gained popularity in recent years. Despite mixed patient and surgeon perceptions, conflicting evidence regarding efficacy and cost-effectiveness in comparison to manual TJA exists. Patients' beliefs surrounding robotic-assisted TJA remain unclear.

View Article and Find Full Text PDF

Background: Peripheral nerve blocks (PNBs) may be utilized for postoperative pain control following total hip arthroplasty (THA). The purpose of this study was to evaluate the association between PNBs and postoperative complication rates, healthcare utilization, and opioid consumption following elective THA.

Methods: Opioid-naive patients who received PNBs on the same day as undergoing THA for degenerative etiologies were identified from a large national database and matched 1:5 to a control cohort using propensity scoring.

View Article and Find Full Text PDF

Optimizing Operating Room Efficiency for Primary Hip and Knee Arthroplasty Using Performance Benchmarks.

Arthroplast Today

February 2025

Division of Orthopaedic Surgery, Department of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, Ontario, Canada.

Background: With increasing demand for total hip arthroplasty (THA) and total knee arthroplasty (TKA), maximizing operating room (OR) efficiency is critical. This paper sought to examine the implementation of time benchmarks when performing primary TKA and THA. We hypothesized that implementing benchmarks would improve efficiency and the number of joints performed per day.

View Article and Find Full Text PDF

Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!