Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Detecting drug-specific IgE (sIgE) is crucial for diagnosing immediate drug-induced hypersensitivity reactions. Basophil activation tests serve as a method to determine the presence of drug-sIgE, highlighting the importance of optimising the assay. Optimisation involves considering multiple factors to ensure sensitisation helps detect an antigen sIgE. The study investigates the complex factors influencing basophil responsiveness thresholds and aims to provide rules-of-thumb guidance for expected results.
Methods: Open and occupied FcεRI receptors were analysed by flow cytometry pre- and postdissociation of surface-bound sIgE. Basophils were then sensitised with serial concentrations of penicillin (BPO)-sIgE in serum or buffer and incubated for 1, 4 and 18 h with or without DO and/or IL-3. Basophil sensitivity was evaluated based on FcεRI receptor densities, sIgE/total IgE (tIgE) ratios, responses to BPO(21)-HSA, and DO and/or IL-3 effects, with maximal responses determined using anti-IgE human antibodies. These optimised conditions were tested with peanut-sIgE and cat-sIgE sera.
Results: Basophils from five donors were used. The FcεRI receptor expression initially averaged 155,000/cell (47,000-344,000/cell), with 35% (5%-79%) unoccupied, which postdissociation increased to 98% (82%-100%) unoccupied. Upon sensitisation, the average reloading with BPO-sIgE was 39% (33%-48%). The ED (a measure of cellular sensitivity) was approx. 6000 BPO-sIgE/cell, and the average maximal anti-IgE antibody response was 58% (25%-68%). A 4-h sensitisation at 4°C with IL-3 pretreatment and 70% DO allowed the detection of BPO-sIgE/tIgE ratios as low as 0.02%-0.05% without spontaneous histamine release. Under the same conditions, responses were detected with 0.33% peanut-sIgE and 0.1% cat-sIgE ratios.
Conclusion: This study outlines a method to assess basophil sensitisation, emphasising the minimum sIgE/tIgE ratio needed for basophil responsiveness. It considers factors like FcεRI open/unoccupied FcεRI receptors, sIgE/tIgE ratios and the effect of DO and IL-3. This sets a strong foundation for refining and advancing basophil activation functional assays.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cea.14594 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!