Effect of fabrication methods and number of supporting teeth on the surface accuracy and dimensional stability of implant surgical guides.

J Prosthet Dent

Professor, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China. Electronic address:

Published: November 2024

Statement Of Problem: Implant surgical guides manufactured using different fabrication methods have been commonly used for computer-guided implant placement. However, how fabrication methods and the number of supporting teeth influence accuracy and stability remains uncertain.

Purpose: The purpose of this in vitro study was to evaluate the influence of fabrication methods and number of supporting teeth on the surface accuracy and dimensional stability of implant surgical guides with 3 different 3-dimensional (3D) printers and 1 computer numeric controlled (CNC) milling machine.

Material And Methods: Two tooth-supported maxillary implant surgical guides with different number of supporting teeth (S: short span with 4 supporting teeth, L: long span with complete arch supporting) were used to fabricate the specimens. Eighty surgical guides were fabricated from 3 different 3D printers and 1 milling machine as follows: group SLA-S (n=10) and SLA-L (n=10) were fabricated with a desktop stereolithography (SLA) 3D printer and photopolymerizing resin; group PolyJet-S (n=10) and PolyJet-L (n=10) were fabricated with a PolyJet 3D printer and photopolymerizing resins; group DLP-S (n=10) and DLP-L (n=10) were fabricated with a desktop digital light processing (DLP) 3D printer and photopolymerizing resin; and group MILL-S (n=10) and group MILL-L (n=10) were fabricated with a 5-axis milling machine and polymethyl methacrylate (PMMA) blanks. All surgical guides were digitized immediately after postprocessing and after 1, 2, and 3 months using a desktop scanner. The congruency between design files and digitized files was quantified with the root mean square (RMS) error with a metrology program (Geomagic Control X). Two-way ANOVA was used to analyze trueness, and the Levene test was used to assess precision (α=.05).

Results: The fabrication methods and number of supporting teeth significantly affected the surface trueness of the guide (P<.001). Milled guides had the lowest mean RMS value for surface trueness, 45 µm for guides with 4 supporting teeth and 59 µm for guides with complete arch supporting. Regarding precision, the Levene test revealed significant difference among fabrication methods (P<.05), while no significant difference was found in the same fabrication method group (P>.05). After 3 months of storage, RMS values increased significantly in the complete arch supporting group comparison of SLA, PolyJet, and DLP (P<.001, P<.001, and P=.015, respectively). RMS values remained similar in other groups.

Conclusions: The trueness and dimensional stability of the surface of the implant surgical guides were affected by fabrication methods and the number of supporting teeth. However, the precision was only affected by fabrication methods. Milled surgical guides showed higher accuracy and better dimensional stability after storage than those produced with 3D printers. Among the groups of 3D printing, guides with 4 supporting teeth showed higher trueness and a lower degree of deformation after storage.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2024.10.031DOI Listing

Publication Analysis

Top Keywords

supporting teeth
24
surgical guides
24
fabrication methods
20
number supporting
20
methods number
16
implant surgical
16
n=10 fabricated
16
teeth surface
12
printer photopolymerizing
12
surface accuracy
8

Similar Publications

Introduction: Guided surgery for immediate anterior implants aims to reduce the time required for aesthetic and functional immediate loading. However, the limited surface area of anterior teeth for guide stabilization may affect the accuracy of implant positioning. This in vitro study evaluated the effect of the number of supporting teeth on the accuracy of immediate implants in the maxillary central incisor region.

View Article and Find Full Text PDF

Chlorhexidine-loaded microneedles for treatment of oral diseases.

Int J Pharm

December 2024

Department of Pharmaceutical Engineering, Azrieli College of Engineering Jerusalem, Jerusalem 9103501, Israel. Electronic address:

Chlorhexidine (CHX) is a gold standard therapeutic agent against clinical oral pathogens. However, its oral use is limited due to unpleasant taste, alteration in taste buds, staining of teeth and mucous membranes. Therefore, CHX-loaded PLGA microneedles (MNs) were fabricated for local and controlled release in the oral cavity, using a casting mold method.

View Article and Find Full Text PDF

Unlabelled: Peri-implantitis (PI) is an inflammatory disease that affects supportive tissues around dental implants, and its progression eventually leads to bone loss and implant failure. However, PI effects may be different based on the presence or absence of adjacent teeth.

Objective: To investigate the differences in bone loss and inflammation between implants placed adjacent to a tooth or edentulous area in a ligature-induced PI model.

View Article and Find Full Text PDF

Booidean snakes are a diverse and widespread lineage with an intriguing evolutionary and biogeographic history. By means of cranial morphology and osteology, this study investigates the evolutionary convergence in the Neotropical genera Boa and Corallus on the one hand and the Malagasy clade comprising Acrantophis and Sanzinia on the other. We hypothesize that the mostly arboreal Corallus and Sanzinia present larger jaws and longer teeth to keep hold of the prey and resist gravity and torsional forces acting on their skull while hanging from branches, while terrestrial genera such as Acrantophis show thinner jaws with shorter teeth because they can rely on the full length of their coils to immobilize and constrict the prey together with a substrate that supports the whole of their body.

View Article and Find Full Text PDF

Residual dentin thickness and biomechanical performance of post-and-core-restored mandibular premolars: A finite element analysis study.

J Prosthet Dent

December 2024

Associate Chief Physician, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China. Electronic address:

Statement Of Problem: Endodontically treated teeth often require post-and-core restorations for structural support because of extensive hard tissue loss. Assessment of the effect of the residual dentin thickness on the biomechanical performance of these restorations is lacking.

Purpose: The purpose of this study was to evaluate the residual dentin thickness in mandibular premolars after post-and-core restorations using cone beam computed tomography (CBCT) and to analyze the stress distribution with finite element analysis (FEA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!