Previous studies have compared single-port robotic cholecystectomy (SPRC) to single-incision laparoscopic (SILC). However, there is not a systematic review and meta-analysis in patient with BMI ≥ 25 kg/m even though higher BMI is a risk factor for gallstone disease, a common indication for cholecystectomy. PubMed, Scopus and Cochrane Library were searched for related literature. Studies and data were extracted by two independent reviewers. Inverse variances weighted mean differences (WMD) with random effects model were used for continues values and odds ratios (OR) with random effects model using the Mantel-Haenszel's formula were used for dichotomous value. Heterogeneity using Higgins I and p values were calculated. Sensitivity analysis was performed for operative duration and intraoperative complications. In this meta-analysis, six studies involving a total of 734 patients examined SPRC and SILC. The analysis revealed a statistically significant increase in operative duration for SPRC compared to SILC, with a weighted mean difference of 26.67 min (95% CI 14.99, 38.34; I = 93%; P < 0.00001; P < 0.00001). Regarding conversion to multi-port cholecystectomy (MC), no statistically significant difference was found, yielding an odds ratio of 0.94 (95% CI 0.36, 2.45; I = 0%; P = 0.78; P = 0.89). Intra-operative blood loss showed non-significant differences, with a weighted mean difference of - 16.76 ml (95% CI - 48.56, 15.03; I = 78%; P = 0.03; P = 0.30). Length of hospitalization was significantly reduced by approximately half a day for SPRC compared to SILC, with a weighted mean difference of - 0.52 days (95% CI - 0.89, - 0.14; I = 0%; P = 0.52; P = 0.007). Intra-operative complications did not differ significantly between the techniques, resulting in an odds ratio of 0.59 (95% CI 0.19, 1.81; I = 70%; P = 0.04; P = 0.36). Finally, two studies evaluated bile leak rates, concluding no significant difference with an odds ratio of 0.86 (95% CI 0.39, 1.88; I = 23%; P = 0.25; P = 0.70). Sensitivity analyses indicated that no single study unduly influenced the results for operative duration, while one study was identified as a source of heterogeneity in intra-operative complications. SPRC is associated with longer operative duration, but shorter length of hospitalization in patients with BMI ≥ 25 kg/m, compared to laparoscopic. Future studies should aim to examine incisional hernias rates as well as determine the long-term outcomes. PROSPERO registration: CRD42024602514.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11701-024-02167-3 | DOI Listing |
Npj Robot
January 2025
Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA.
Single-port surgical robots have gained popularity due to less patient trauma and quicker post-surgery recovery. However, due to limited access provided by a single incision, the miniaturization and maneuverability of these robots still needs to be improved. In this paper, we propose the design of a single-port, dual-arm robotically steerable endoscope containing one steerable major cannula and two steerable minor cannulas.
View Article and Find Full Text PDFSci Rep
January 2025
Division of Breast Surgery, Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-Gu, Seoul, 05505, Republic of Korea.
We investigated the safety and performance of the Da Vinci SP single-port robot (SP robot) in nipple-sparing mastectomy (NSM) with immediate reconstruction. Medical records of 60 women aged ≥ 19 years who had undergone SP robot-assisted unilateral or bilateral NSM with immediate reconstruction between October 2020 and August 2021 were retrospectively analyzed. Stage I (31, 47.
View Article and Find Full Text PDFAsian J Endosc Surg
December 2024
Department of Gastric Surgery, National Cancer Center Hospital, Tokyo, Japan.
Background: Robotic surgery may have shown advantages over conventional laparoscopic surgery, but the da Vinci SP system, which utilizes a single incision, has had limited use in gastric cancer surgery. This study aims to evaluate the short-term outcomes of a novel hybrid technique, minimally invasive laparoscopic and robotic surgery (MILAR), with the da Vinci SP system for gastric cancer.
Materials And Methods: This retrospective study reviewed 23 consecutive patients who underwent gastrectomy for gastric cancer using the MILAR technique with the da Vinci SP system between May and October 2024.
Int J Med Robot
February 2025
Division of Colorectal Surgery, Department of Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
Background: Single port robotic platform offers articulation and 360° camera rotation for anorectal tumour excision in a narrow pelvic space. This study assesses the clinical usefulness and outcomes of SP robotic transanal surgery.
Methods: Nine patients who underwent transanal excision using the SP robotic platform were included.
J Neurosurg Pediatr
December 2024
2Fetal Medicine Division, Hospital e Maternidade Santa Joana, São Paulo; and.
Objective: The authors aimed to describe a low-cost and easily reproducible alteration of the Bruner and Tulipan procedure to preserve uterine muscular fibers. They conducted a retrospective cohort study of 10 pregnant women whose fetuses developed lumbosacral myelomeningocele (MM). The MM was repaired through a fetal neurosurgical procedure using a tubular single-port endoscope-assisted technique.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!