Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In this study, erbium-doped fiber (EDF) and Panda-type polarization maintaining erbium-doped fiber (PM-EDF) were fabricated from the same erbium-doped preform. The intrinsic influence of stress induced by the Panda-type design on the optical properties was investigated. A local structural model of EDF was developed to simulate the introduction of stress by varying the length of non-bridging oxygen (NBO) bonds between erbium ions (Er) and the silica network, providing theoretical insights. An increase in bond length (indicative of tensile stress), results in decreased excitation and emission intensities for EDF, and the peaks exhibit redshifts. Conversely, a decrease in bond length (indicative of compressive stress), leads to increased excitation and emission intensities, with the peaks showing blueshifts. Experimentally, PM-EDF demonstrated a lower absorption coefficient compared to EDF, with absorption peaks experiencing redshifts of approximately 2 nm. Furthermore, the emission intensity was diminished, and the emission peak at 1530 nm displayed a redshift of around 3 nm. The fluorescence lifetime was shortened to 9.99 ms. Additionally, the total gain of PM-EDF decreased by approximately 4 dB, and the bandwidth narrowed by roughly 13%. The experimental outcomes largely align with the simulation predictions, further corroborating the significant impact of stress on the optical properties of PM-EDF.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.527379 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!