Achieving high operating temperature (HOT) plays a crucial role in miniaturizing type-II superlattice (T2SL) mid-wavelength infrared (MWIR) focal plane arrays (FPAs). However, their full potential has yet to be realized due to a lack of complete understanding of their operation from the perspective of detection principles. Here, by investigating the photon transmission path and optoelectronic performance of the simulated devices, a detailed noise equivalent temperature difference (NETD) model of the T2SL MWIR FPAs was established. The NETD limitations in the optics-limited and detector-limited modes were revealed by studying the effects of the source, optical system, and FPA-related parameters. Although NETD exhibits sensitivity to dark currents, improvements in the quantum efficiency and well capacity can further boost its performance. When the defects and carrier lifetimes are well controlled to completely suppress the dark current, the NETD of an MWIR system with optimized integration times, which operates between 150 K and 200 K, is predicted to be below 10 mK when detecting room-temperature targets. The results provide new insights into the model and sources contributing to the NETD and demonstrate the possibility of high-temperature operation of T2SLs MWIR FPAs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.530474 | DOI Listing |
Quant Imaging Med Surg
January 2025
Department of Imaging Medicine and Nuclear Medicine, Shandong Second Medical University, Weifang, China.
Background: Rapid kilovolt (kV)-switching dual-energy computed tomography (DECT) has been increasingly applied to the measurement of lumbar spine bone mineral density (BMD) in humans and animal models. The objective of this study was to investigate the optimal parameters for the measurement of vertebral BMD. The BMD of the spinal model was measured by means of DECT in combination with different noise index (NI) and preset adaptive statistical iterative reconstruction Veo (ASiR-V) levels.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, 2-1-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan; Department of Orthopaedics, Faculty of Medicine, Juntendo University, 2-1-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan.
Background: Although hearing loss in orthopaedic surgeons from exposure to hammering sounds have been previously reported, there are no reports on the noise environment during total hip arthroplasty (THA) in Japan. The aim of this study was to investigate the sound level generated by cementless THA in Japan, and to discuss the broader sound environment within this space.
Methods: 94 cementless THAs (94 patients with informed consent) performed by four surgeons were included.
Environ Res
January 2025
Barcelona Institute for Global Health, Barcelona, Spain; Universitat Pompeu Fabra, Barcelona, Spain; CIBERESP, Madrid, Spain.
This study aimed to develop exposure-response relationships (ERRs) between road, rail, and air traffic noise and high noise annoyance (HNA) and to assess the HNA disease burden. In 2023, 4 640 adults were cross-sectionally sampled from the five largest cities in Bulgaria. Participants' road, rail/tram, and air traffic HNA was defined as the top two categories (60% cut-off point) of a 5-point scale.
View Article and Find Full Text PDFNatl Sci Rev
January 2025
Research Institute of Superconductor Electronics, School of Electronic Science and Engineering, Nanjing University, Nanjing 210023, China.
The noise equivalent temperature difference (NETD) indicates the minimum temperature difference resolvable by using an infrared detector. The lower the NETD, the better the sensor can register small temperature differences. In this work, we proposed a strategy to achieve a high temperature resolution using a superconducting nanowire single-photon detector (SNSPD) with ultra-high sensitivity.
View Article and Find Full Text PDFSci Rep
January 2025
Institute of Noise and Vibration, Naval University of Engineering, Wuhan, 430033, China.
To suppress the significant vibration line spectra of piping systems under multi-frequency harmonic excitations, a novel dynamic vibration absorber (NDVA) is designed. The NDVA integrates numerous independent resonant units within a finite space through an ingenious structural design and possesses rich frequency regulation characteristics. A vibration model of the piping system equipped with the NDVA is established, and the approximate equivalent parameters of both the piping and the resonant units are inverted based on the frequency response function (FRF) test results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!